TEMPERATURE RANGE

Outdoor: -40

º

F to 158

º

F; -40

º

C to 70

º

C

Indoor: 32

º

F to 122

º

F; 0

º

C to 50

º

C

HUMIDITY RANGE

Outdoor: 1% to 99% RH
Indoor: 1% to 99% RH

WIRELESS RANGE

330 ft / 100 m 

depending on home construction materials

OPERATING FREQUENCY

433 MHz

POWER

Display: 5vdc power adapter 

3 x AA alkaline batteries (optional)
Sensor: 2 x AA alkaline or lithium batteries

DATA REPORTING

Outdoor: 16 second updates
 Indoor: 60 second updates

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

1- This device may NOT cause harmful interference, and

2- This device must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the 

user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 

rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip-

ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. 

Such modifications could void the user authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s).

Operation is subject to the following two confitions:

(1) This device may not cause interference, and

(2) This device must accept any interference received, including interference that may cause undesired operation of the device.

Specifications

Summary of Contents for 02030RM

Page 1: ...2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Intelli Time Clock 7 Set the Time Date Units 7 Backlight Settings 7 Placement Guidelines 8 Using the Weather Station 9 Troubleshooting 10 Care Maintenance 12 Calibration 12 Replace Intelli Time Battery 13 Specifications 14 FCC Information 14 Customer Support 15 Warranty 15 Weather Station models 02030RM...

Page 2: ... with tabletop stand 2 Outdoor sensor 3 Instruction Manual 4 Power adapter PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Features Benefits 4 3 2 1 5 OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 Wireless Signal Indicator Flashes when data is being sent to the d...

Page 3: ...umidity 7 Current Indoor Temperature 8 Moon Phase 9 Auto Icon Indicates display backlight AUTO DIM mode activated 10 Day of the Week 11 Display Low Battery Indicator 12 Date 13 Time 14 Current Barometric Pressure Arrow icon indicates the direction pressure is trending 15 12 to 24 Hour Weather Forecaster Self Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forec...

Page 4: ...references 4 Button for setup preferences 5 A B C Switch ID code that must match sensor s A B C switch to ensure units synchronize 6 Reset Full reset to factory defaults 7 Plug in For Power Adapter 8 Battery Compartment 9 Intelli Time Battery Compartment 10 Battery Compartment Cover 2 1 3 4 5 6 7 8 9 10 Features Benefits ...

Page 5: ... rechargeable batteries are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartment 2 Insert 2 x AA batteries into the batt...

Page 6: ...ries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize Install or Replace Backup Batteries optional 1 Remove the batte...

Page 7: ...R TEMPERATURE SCALE ºF or ºC BAROMETRIC PRESSURE SCALE inHg or hPa If you live in an area that observes daylight saving time DST should be set to ON even if it is not currently Daylight Savings Time You will automatically exit SETUP MODE if no buttons are pressed for 20 seconds Enter setup mode at any time by pressing the SET button Display Backlight Settings This weather station s color display f...

Page 8: ...e a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any heat sources or vents Display unit and outdoor sensor must be within 330 ft 100 m of each other To maximize wireless r...

Page 9: ...the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISING Moon Phase Track the phases of the moon conveyed through simple lunar phase icons High Low Records Today s high and low records are displayed for indoor and outdoor temperature and humidity Today s records automatically clear at 12 00am midnight every day View today s high or low rec...

Page 10: ...doors and remove batteries from each 2 Make sure the A B C switch on both units match 3 Reinstall batteries in the outdoor sensor 4 Reinstall batteries in the display unit 5 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Sometimes changing to a different channel can help Inaccurate forecast Weather Forecast icon predicts conditions for the nex...

Page 11: ... that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset The unit lost power or batteries were changed and the time is not correct The Intelli Time battery needs to be replaced see page 13 Once the new battery is installed time and date wil...

Page 12: ... the or buttons to calibrate the data value higher or lower from the actual reading 4 Press the Set button to confirm the calibration adjustment The icon will remain illuminated next to calibrated values 5 The next adjustable data will begin flashing indicating it is ready to be calibrated Repeat Steps 1 4 to calibrate additional data After 20 seconds of inactivity the display will save the adjust...

Page 13: ...tery compartment as shown Install battery with positive terminal facing OUT 3 Screw in the battery cover 3 Press the or buttons to calibrate the pressure higher or lower 4 Press the Set button to confirm the calibration adjustment Note The icon will remain illuminated next to the calibrated value After 20 seconds of inactivity the display will save your adjustments and exit calibration mode Note C...

Page 14: ...on This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turn...

Page 15: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Page 16: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 02030 INST 092314 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers C...

Reviews: