BACK OF DISPLAY UNIT

1.  CLEAR TODAY Button 

  

Clears data recorded since 12:00am.

2.   RESET Button 

 

Full reset to factory defaults. 

3.  A-B-C Switch 

 

 ID code that must match 3-in-1  

 

sensor’s A-B-C switch to ensure  

 

units synchronize.

4.  RESET REC Button 

 

Resets all readings except time  

 

& date.

5.  Battery Compartment
6.  Battery Compartment Cover

Back of Display Unit

1

2

3

4

5  

6

Summary of Contents for 00639W

Page 1: ...res Benefits 3 in 1 3 Features Display Unit 4 Setup 7 3 in 1 Sensor Setup 7 Display Unit Setup 8 Set the Time Date 9 Measurement Units 10 Placement Guidelines 11 3 in 1 Sensor Installation 12 Using the Weather Center 13 Programmable Alarms 14 Troubleshooting 15 Care Maintenance 16 Specifications 17 FCC Information 17 Customer Support 18 Warranty 18 Weather Center model 00639W Instruction Manual ...

Page 2: ... film that is applied to the LCD screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 3 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Reg...

Page 3: ...ver for Battery Access 3 Mounting Point 4 Wind Speed Anemometer 5 Mounting Hardware Includes anchors and screws Qty Diameter Length 4 4 1 1 6 or 8 1 4 or 3 8 6 Mounting Bracket 7 A B C Switch not shown ID code that must match display s A B C switch to ensure units synchronize 4 1 2 3 6 5 ...

Page 4: ...4 Features Benefits Display Unit 1 2 3 4 5 6 7 8 9 10 31 12 11 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 1 28 29 30 1 ...

Page 5: ...and change settings 13 SET Button For setup preferences 14 Selectable Category 15 Button Press to select Category shown in 14 and change settings 16 Records Button Press for all time low and date recorded for current category selected on display 14 Press twice for all time high and date recorded 17 Display Stand 18 Record Lows Shown for current category selected on the display 14 19 Clear Button D...

Page 6: ...2 RESET Button Full reset to factory defaults 3 A B C Switch ID code that must match 3 in 1 sensor s A B C switch to ensure units synchronize 4 RESET REC Button Resets all readings except time date 5 Battery Compartment 6 Battery Compartment Cover Back of Display Unit 1 2 3 4 5 6 ...

Page 7: ...nsor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the 3 in 1 sensor for temperatures below 4ºF 20ºC 1 Press the release lever and pull off the lower housing of the sensor 2 Remove the battery compartment cover 3 Insert 4 x AA batteries into the battery compartment as shown Follow the polarity...

Page 8: ...batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup AcuRite recommends high quality alkaline batteries for the best product performance Heavy duty or rechargeable batteries are not recommended Set the A B C Switch Locate the A B C switch inside the battery compart...

Page 9: ... confirm hour selection 5 Press the or buttons to adjust minutes 6 Press the SET button to confirm minute selection The clock is now set Set the Date 1 Press the or buttons until SET DATE is displayed on the Selectable Category part of the display unit 2 Press the SET button to set the date 3 Press the or buttons to adjust the month 4 Press the SET button to confirm month selection 5 Press the or ...

Page 10: ... 1 Press the or buttons until SET UNITS is displayed on the Selectable Category part of the display unit 2 Press the SET button to set the unit preference 3 Press the or buttons to select STAND for standard or METRIC for metric units 4 Press the SET button to confirm your selection Units are now set ...

Page 11: ...ts away from large metallic items thick walls metal surfaces or other objects that may limit wireless communication PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet 9 m away from electronic devices TV computer microwave radio etc LOCATE AWAY FROM HEAT SOURCES Position sensor away from heaters air conditioners chimneys exhaust vents asphalt and concrete surfaces that radiate heat LOCA...

Page 12: ...ten the lower sensor housing to the mounting base 3 Make sure the sensor is level using a bubble level 4 Fasten mounting base to a post or railing using 2 screws Pipe Mount 1 Insert pipe we recommend 3 4 schedule 40 PVC 25 8 mm O D not included or similar item all the way into the hole on the bottom of the sensor Note Mounting base is not used 2 Use one of the screws included in the hardware bag t...

Page 13: ...ariable History Chart The multi variable history chart lets you monitor the change in conditions over the last 12 hour time period 12 6 3 2 1 0 Toggle between outdoor temperature and humidity wind speed peak and average wind speeds and barometric pressure readings Wind Speed The Wind Speed area of the display features the CURRENT speed as well as the AVERAGE and PEAK wind speeds AVERAGE wind speed...

Page 14: ...value only applies to alarms that require a value press AND HOLD the ALARM ON OFF button until the SET indicator appears in the area of the display labeled ALARM left of the selected weather category and the alarm setting flashes 3 Adjust the alarm value by pressing the or buttons 4 Press the SET button to confirm a value 5 The alarm ON indicator will highlight on the display Alarm is now programm...

Page 15: ...n a couple feet of each other for about 20 minutes to gain a strong connection Outdoor temperature is flashing or showing dashes Flashing of the outdoor temperature may be an indication of wireless interference Make sure the A B C switch in the battery compartments of both the display unit and sensor are switched to the same letter You may choose A B or C but both units must match to sync up Inacc...

Page 16: ...both units are positioned away from moisture sources see p 11 Make sure 3 in 1 sensor is mounted at least 5 ft off of the ground Care Maintenance Display Unit Care Clean with a soft damp cloth Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture Clean ventilation ports regularly with a gentle puff of air 3 in 1 Sensor Care Clean the Sensor Clean with a soft damp cloth Do ...

Page 17: ...st harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or t...

Page 18: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Page 19: ...19 ...

Page 20: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 00639 INST 102014 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers C...

Reviews: