2 SaFETY GUIDELINES aND WaRNINGS

2.1 WaRNINGS aND SYMbOLS

Safety instructions and warnings are marked in this manual 
by the following pictograms:

   

A procedure, circumstance, etc which deserves  

   

extra attention.

  
  

CaUTION!

  

   

Special information, commands and 

   

prohibitions in order to prevent damage.

  

WaRNING

   

A WARNING refers to possible injury to the  

   

user or installer or significant material damage  

   

to the Soladin Web DC Switch if the installer /  

   

user does not (carefully) follow the stated  

  

procedures.

2.2 USE FOR INTENDED PURPOSE

Use the Soladin Web DC Switch only in installations that 
meet these qualifications: 
• in permanent installations;  
• the electrical installation must meet the applicable regula-
tions and standards, must be carried out correctly and must 
be in a good condition; 
• according to the technical specifications.

WaRNING

Never use the Soladin Web DC Switch in situ-
ations where there is danger of gas or dust 
explosion or potentially flammable products! 

Use of the Soladin Web DC Switch other than 
as mentioned under § 2.2 is not considered to 
be consistent with the intended purpose. Mas-
tervolt does not hold itself liable for any damage 
resulting from the above.

2.3 ORGaNISaTIONaL MEaSURES

The installer / user must always: have access to this manual; 
be familiar with the contents of this manual. This applies 
particularly to Chapter 2, Safety Guidelines & Warning.

2.4 INSTaLLaTION, MaINTENaNCE aND REPaIR

  
  

WaRNING

As high voltages exist, only allow installation, 
maintenance and repair of the Soladin Web DC 
Switch and changes in your electrical system to 
be carried out by qualified electricians. Con-
nections and safety features must be executed 
according to the locally applicable regulations. 
If such are required, only use original spare 
parts

Use the special Amphenol tool when taking the 
Amphenol connectors apart.

2.5 WaRNING OF SPECIaL DaNGERS

The voltages present at both sides of the 
Soladin Web DC Switch and inside the 
enclosure are not safe to touch. Do not work 
on the Soladin Web DC Switch and/or the 
electrical installation if it is still connected to 
the PV panels or the inverter. Allow time for the 
inverter capacitors to de-energize. Verify de-
energizing of all connections using a suitable 
metering instrument.Make sure two persons 
are present when working on an installation, 
at least until the installation has been de-
energized and verified by a suitable metering 
instrument.

Summary of Contents for MASTERVOLT Soladin Web DC Switch

Page 1: ...BRUIKERS EN INSTALLATIEHANDLEIDING P9 DE BEDIENUNGS UND INSTALLATIONSANLEITUNG P17 FR MANUEL UTILISATEURS ET D INSTALLATION P25 ES MANUAL DEL USUARIO Y DE INSTALACIÓN P33 IT MANUALE DI USO E MANUTENZIONE P41 10000006477 01 Soladin Web DC Switch ...

Page 2: ...ut plus to Soladin 2 Input plus from PV string 3 Output minus to Soladin 4 Input minus from PV string G PE terminal positive input 2x N PE terminal minus input 2x S Switch knob 0 Switch Off position I Switch On position OVERVIEW Soladin Web DC Switch 1 3 2 4 0 I ON N N O F F ON G G S ...

Page 3: ... 4 1 9 INSTALLATION ENVIRONMENT 4 1 10 DC CONFIGURATION 4 2 SAFETY GUIDELINES AND WARNINGS 5 2 2 USE FOR INTENDED PURPOSE 5 2 4 INSTALLATION MAINTENANCE AND REPAIR 5 2 5 WARNING OF SPECIAL DANGERS 5 3 INSTALLATION AND COMMISSIONING 6 3 1 THINGS YOU NEED FOR INSTALLATION 6 3 2 INSTALLATION STEP BY STEP 6 3 3 COMMISSIONING AFTER INSTALLATION 6 3 4 DE COMMISSIONING 6 3 5 MAINTENANCE 6 3 6 PV groundin...

Page 4: ...is warranty For making an appeal on warranty you can contact your supplier directly stating your complaint application date of purchase and part number serial number 1 5 LIABILITY Mastervolt accepts no liability for consequential damage of using the Soladin Web DC Switch possible errors in the manuals and their results 1 6 CHANGES TO THE Soladin Web DC Switch Changes to the Soladin Web DC Switch m...

Page 5: ...se Mas tervolt does not hold itself liable for any damage resulting from the above 2 3 ORGANISATIONAL MEASURES The installer user must always have access to this manual be familiar with the contents of this manual This applies particularly to Chapter 2 Safety Guidelines Warning 2 4 INSTALLATION MAINTENANCE AND REPAIR WARNING As high voltages exist only allow installation maintenance and repair of ...

Page 6: ...urn the screws clockwise to tighten the lid Fix the top screw first hang the Soladin Web Switch into position Then fix the bottom screw 3 3 COMMISSIONING AFTER INSTALLATION Move the DC switch to the ON position vertical 3 4 DE COMMISSIONING If it is necessary to take the Soladin Web DC Switch out of operation follow these steps 1 Turn the switch to the 0 Off position 2 Disconnect the PV connectors...

Page 7: ...tensive overview of all our products 4 TECHNICAL DATA 4 1 TECHNICAL SPECIFICATIONS GENERAL SPECIFICATIONS Model Soladin Web DC Switch Part number 130500640 Operating temp 20 C 45 C 4 F 113 F Protection degree IP 66 Relative humidity 4 90 condensing Safety class Class II Weight 450 g including cables Dimensions See figure 4 1 SOLAR IN OUTPUT DC Maximum input output voltage 400 V DC Maximum input ou...

Page 8: ... 1105 AN Amsterdam The Netherlands Declare under our sole responsibility that the product Article number Product name 130500640 Soladin Web DC Switch is in conformity with the provisions of the following EC directives 2006 95 ec LV directive 2004 108 ec EMC directive 2011 65 eu ROHS directive The following harmonized standards have been applied iec 60947 1 iec 60947 3 Amsterdam Ing D R Bassie Prod...