Installation & Commissioning Guide - ESP Platinum ID Split Ducted Units 

Doc. Part No. 0525-052  

Rev. 5  200928

Page 16 of  20

KEY PARTS LIST

 

  ESP PLATINUM MODELS

ERQ2-14AS

ERQ3-17AS

ERQ4-19AS

ITEM

DESCRIPTION

PART

NUMBER

QUANTITY

QUANTITY

QUANTITY

1

EC ID Fan

2520-333

1

1

---

2

EC ID Fan

2520-334

--

--

1

3

Indoor Coil Assembly

1040-156

1

---

---

4

Indoor Coil Assembly

1040-254

---

1

---

5

Indoor Coil Assembly

1040-177

---

----

1

6

Coil Piston

4540-088

1

---

---

7

Coil Piston

4540-098

---

1

---

8

Coil Piston

4540-128

---

---

1

  9

ID Control Board - AFS-QUEIB1-1

2020-154

1

1

1

10

Zone Module

8Z-VAQ

1

1

1

11

Filter Board

4080-013

1

1

1

12

Yellow Cat5e Cable 10m

4070-028

1 per controller 1 per controller 1 per controller

Summary of Contents for ERQ2-14AS

Page 1: ...en consent from Actron Air Please Read This Guide Congratulations on your purchase of an Actron Air air conditioning unit This unit has been designed and manufactured with the highest quality standard in mind Please read this guide thoroughly and keep it near the unit for future reference INDOOR UNITS ESP PLATINUM Single Fan Coil Split Fan Coil ERQ2 14AS FRQ4 19AS ERQ3 17AS ARV4 19AS ERQ4 19AS Spl...

Page 2: ...re that unit installation complies with relevant council regulations and building code standards council regulations and building code standards 4 4 All electrical wiring must be in accordance with All electrical wiring must be in accordance with current electrical authority regulations and all wiring current electrical authority regulations and all wiring connections to be as per electrical diagr...

Page 3: ...are subject to change without notice Copyright 2017 Actron Engineering Pty Ltd Page 3 of 20 COMPONENTS OVERVIEW INDOOR UNIT COMPONENTS OVERVIEW EC Motor Fans Coil 8Z VAQ Module Lid Control Panel Control Panel SRD175C SRD175E UMMARY SRD175C SRD175E L SCROLL RESSOR ED UNIT Unit Control Board EMC Filter ...

Page 4: ...3 Minimum Service Access Areas and Spaces for Airflow Clearances are responsibilities of the installer ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow THIRD ANGLE PROJECTION STACKING OF UNITS ONE IN FRONT OF THE OTHER DISTANCE BET C A SIDE BY SIDE DISTANCE BET B A DUCT WORK 800 mm HEIGHT CLEARANCE 340 DUCT WORK DUCT WORK 800 mm SERVICE C...

Page 5: ...TURN AIR EC INDOOR FAN EC INDOOR FAN 11 1315 MTG C C DIST 11 TOP VIEW FRONT VIEW SIDE VIEW HEIGHT CLEARANCE 410 DUCT WORK DUCT WORK 800 mm SERVICE CLEARANCE 800 mm SERVICE CLEARANCE ELECTRICAL EC ID FAN EC ID FAN INDOOR COIL A B C D NOTES 1 Do not scale drawing All dimensions are in mm unless specified Refer to corresponding unit dimensional drawing for mounting hole details 2 Service Access Areas...

Page 6: ...S ONE IN FRONT OF THE OTHER DISTANCE BET C A SIDE BY SIDE DISTANCE BET B A 800 mm DUCT WORK 800 mm SERVICE CLEARANCE TOP VIEW DUCT WORK TO FAN SECTION 0m Min 6m Max COIL SECTION DUCT WORK 800 mm SERVICE CLEARANCE HEIGHT CLEARANCE 410mm A B C D NOTES 1 Do not scale drawing All dimensions are in mm unless specified Refer to corresponding unit dimensional drawing for mounting hole details 2 Service A...

Page 7: ...FRONT OF THE OTHER DISTANCE BET C A SIDE BY SIDE DISTANCE BET B A 800 mm DUCT WORK UNIT MODEL NUMBER UNIT WEIGHT kg FRQ4 19AS 46 A B C D NOTES 1 Do not scale drawing All dimensions are in mm unless specified Refer to corresponding unit dimensional drawing for mounting hole details 2 Service Access Areas and Spaces for Airflow Clearances given are suggested minimum based on the condition that the s...

Page 8: ...AIR DUCT OPTIONAL Supply Air plenums and Duct Plates twin spigot are available in order to facilitate your duct system connection to the indoor unit The supply air plenums come in 1 way 2 way and 3 way options which offer a wider solutions to your different air distribution requirements SPLIT FAN COIL SYSTEM OPTIONAL ERQ4 19AS The Actron Air innovative 2 piece fan coil system provides a solution t...

Page 9: ...prevent the unit from being damaged during lifting 4 Test lift the unit to determine exact unit balance and stability before hoisting it to the installation location A CRANE LIFTING METHOD NOTE Crane lifting method is recommended for high rise lifting Fig 1 Connect the loop ends of slings unto shackle Fig 2 WH S regulations must be observed and will take precedence during lifting process WARNING M...

Page 10: ...URN AIR INDOOR COIL CONDENSATE DRAIN MUST BE RUN SEPERATLY FROM THE SAFETY TRAY DRAIN SAFETY TRAY DRAIN CONNECTION CONDENSATE DRAIN CONNECTION SUPPLY AIR INTERNAL CONDENSATE TRAY THE TOP OF THE P TRAP MUST BE 50MM BELOW THE TOP OF THE CONDENSATE DRAIN CONNECTION THE TOP OF THE P TRAP MUST BE 50MM BELOW THE TOP OF THE CONDENSATE DRAIN CONNECTION INSTALL A T PIECE AS AN AIR VENT FOR LONG DRAIN RUNS ...

Page 11: ...TH M SERIES CONTROLS ONLY 24 VOLT 8 ZONE KIT 8Z 24V AMZ 24V ZONE CARD 20VA 240 TO 24 VOLT TRANSFORMER INSTALLATION INSTRUCTIONS MOUNTING SCREWS LENGTH OF ALL BARRELS MEASURE 290 mm DIMENSIONS ALL INTEGRATED ZONE BARRELS COME INDIVIDUALLY BOXED FOR SAFE TRANSPORT INCLUSIONS 8Z 24V 8 ZONE KIT 8Z 24V ZONE MODULE INSTALLATION INSTRUCTIONS Duct Duct Zone Barrel Damper Motor on Top of the Zone Barrel TY...

Page 12: ...8 ZONE 7 ZONE 6 ZONE 5 ZONE 4 ZONE 3 ZONE 2 ZONE 1 TO ZONE 2 8 240V MAINS ZONE MOTOR ZONE CONTROL 1 REMOTE SENSOR 1 LOG RJ45 SOCKETS FOR ACTRON AIR CAT5E SPEC CABLES ONLY REFER TO QUE CONTROL SYSTEM INSTALLATION COMMISSIONING MANUAL FOR ALL AVAILABLE CONFIGURATIONS FIELD WIRING RF RF OPTIONAL WIRED CONNECTION POWER ONLY CUT OFF SCREEN WIRE TO OUTDOOR UNIT 8Z VAQ DATA CABLE GREEN CAT5E CABLE THIS I...

Page 13: ...nd cable boots Yellow FIELD WIRING BY INSTALLER 2 CORE 7 0 30 0 5mm2 Twisted Pair Shielded Data Cable with Screen Foil clamped to a Metal P Clip OUTDOOR UNIT TO OUTDOOR PCB MODEL MEPS CERT I FI ED A U S TRALIAN M A D E A U STRALIAN OW N E D R 410A LIVE ELECTRICAL WITHIN ENCLOSURE ISOLATE ELECTRICAL SUPPLY BEFORE REMOVING PANELS AUTHORISED TECHNICIANS ONLY 1 DIAGRAM SHOWING SCREEN FOIL CLAMPING Met...

Page 14: ...LY BOXED FOR SAFE TRANSPORT INCLUSIONS 8Z 24V 8 ZONE KIT 8Z 24V ZONE MODULE INSTALLATION INSTRUCTIONS MOUNTING SCREWS ITEM PART NUMBER 7 METER CABLE 4070 004 ZONE MOTOR ONLY TRANSFORMER ONLY ZM 24V 2045 046 20 METER CABLE 4070 007 2 WAY RJ45 JOINER 2045 121 3 WAY RJ45 JOINER 4070 008 ZONE OPTION 2 1 5V AAA 1 5V AAA 1 5V AAA 1 5V AAA TYPE 10 250 mm PART NUMBER ZB 10 250 INTEGRATED ZONE BARREL PART ...

Page 15: ... Yrs 3 Yrs 4 Yrs 5 Yrs Casing Panels and Frames Visual check for damage rust and dust accumulation For highly corrosive environment wash panels quarterly with water and neutral detergent solution Wax panels Repair re paint where required Insulation Visual check for insulation conditions Repair replace insulation material Fan Visual check for run out of balance and dust attached Clean off dust as n...

Page 16: ...Y QUANTITY 1 EC ID Fan 2520 333 1 1 2 EC ID Fan 2520 334 1 3 Indoor Coil Assembly 1040 156 1 4 Indoor Coil Assembly 1040 254 1 5 Indoor Coil Assembly 1040 177 1 6 Coil Piston 4540 088 1 7 Coil Piston 4540 098 1 8 Coil Piston 4540 128 1 9 ID Control Board AFS QUEIB1 1 2020 154 1 1 1 10 Zone Module 8Z VAQ 1 1 1 11 Filter Board 4080 013 1 1 1 12 Yellow Cat5e Cable 10m 4070 028 1 per controller 1 per ...

Page 17: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 18: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 19: ...THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 20: ...Ltd ABN 34 002 767 240 HEAD OFFICE SYDNEY AUSTRALIA Printed in Australia Part No 0525 052 Rev No 5 0 200928 1800 119 229 actronair com au Copyright 2017 Actron Engineering Pty Ltd Refrigerant Trading Authorisation No AU06394 ...

Reviews: