Connections and Mounting Hardware
The IF input connection requires a coaxial cable with an F or N type connector. The RF output requires a
waveguide with a CPR-137G flat flange. An O-ring shall be used to seal the waveguide connection.
Assembly and Installation
Use the information in this section as a guide to assemble and install the block up converter. The
specified humidity is up to 100% during operation. However, installation should be carried out in dry
conditions, free of salt spray or excessive humidity. This will eliminate the possibility of moisture and
other foreign substances from entering the output waveguide flange.
Only authorized technical personnel should perform the Installation and
proper electrical hookups of the block up converter.
The
block
up
converter
is
designed
to
operate
in
an
outdoor
environment
and
is
waterproof
when
mounted
in
the
correct
orientation.
To
provide
a
sufficient
airflow,
the
block
up
converter
should
be
mounted
with
a
minimum
clearance
of
3
inches
on
all
four
sides
and
the
bottom.
Adequate
cooling
for
the
block
up
converter
will
provide
years
of
top
performance.