activTek INDUCT 2000LV Owner'S Manual Download Page 2

(8) #8 - .75
1/4” Self-tapping screws
Item # US70679

(4) #6 - 32 X 2 inch
Threaded bolts
Item #US70680

(4) #6 - 32
Toggle bolt wall anchors
Item # US70682

(4) #8 - 32
Hex nuts
Item # US70681

Safety 

Switch

CONTENTS

2

3

on your purchase of an InDuct 2000 LV air 
purification enhancement system. This unit 
is designed to be installed into an existing 
HVAC system. Please read and follow all service 
procedures outlined in this manual. Use only 
genuine activTek replacement parts available 
from your Distributor.

If you have any questions concerning this or any 
activTek product, contact your Distributor.

Please record the name and phone number of 

your activTek Distributor: 
Name __________________________________

Phone _________________________________
Please record the serial number of your InDuct 

2000 LV:
Serial # _________________________________

CONGRATULATIONS . . .

REPLACEMENT PARTS

Base Unit

• Ozone-Free ActivePure® Cell

  Item # US71088

• Ballast

  Item # 9950102

• Power Cord

  Item # 9950103

INSTALLATION HARDWARE (SUPPLIED)

This owner’s manual is also available online at:  

http://www.activTek.net.

activTek Environmental,  300 East Valley Dr., Bristol, VA 24201,  www.activTek.net

ASP_BL_62-00000_V

A-00000_0

312

HG-LAMP CONTAINS MERCURY. Manage in 

accordance with disposal laws: www.lamprecycle.org. 

activTek INDUCT 2000 LV

24 volt, Item # 00000000

RESIDENTIAL HVAC AIR PURIFICATION SYSTEM

UV bulb indicator

Replaceable ActivePure® 

Cell (includes UV Lamp)

Mounting

Plate

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 2
About Induct 2000 LV  . . . . . . . . . . . . . . . . . . 2
Product Contents. . . . . . . . . . . . . . . . . . . . . . . 3
Installation Hardware. . . . . . . . . . . . . . . . . . . 3
Replacement Parts  . . . . . . . . . . . . . . . . . . . . . 3
Recommended Installation Tools. . . . . . . . 3
Installation Requirements. . . . . . . . . . . . . . . 4
Metal Ductwork Installation  . . . . . . . . . . . . 5
Fiberglass Ductwork Installation . . . . . . . . 6
Maintenance/UV Lamp Indicator. . . . . . . 12
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Changing the ActivePure® Cell . . . . . . . . . 13
Changing the Ballast  . . . . . . . . . . . . . . . . . . 14

Features:

Ozone Production:

•  0.02 ppm maximum with standard 

replaceable ActivePure® Cell.

•  0.00 ppm with ozone-free 

replaceable ActivePure® Cell.

Electrical:

•  18-32VAC ~50/60Hz

•  Current: 1.0A,

•  Power Factor: 0.99

•  Power: 18 Watts

Mechanical:

• Distribution via air handler.

Dimensions:

•  8.5” x 8.5” x 11”  

(21.59cm x 21.59cm x27.94cm) 

• Weight: 3 pounds (1.2 kg.)

Operating Temperature:

•  32-120°F

 

Coverage:

• Up to 2000 ft

2

 (186 m

2

)

 

Warranty:

•  Limited 3 years.

SPECIFIC

A

TIONS

   

InDuct 2000 LV by activTek is easily mounted into 

the supply side of air conditioning and heating 

system air ducts where many problems can start. 

Optional ozone-free units are available with the same 

basic components and an ozone-free bulb. Note that 

odor reduction is dependent on low level ozone. The 

InDuct 2000 LV provides 0.02 ppm or less of ozone. If 

odor reduction is required, the standard ActivePure® 

Cell is recommended.

Location for Protective Earth Line.

WARNING!

 - UV Light in operation. 

Disconnect unit from power supply before 

servicing. Failure to follow warnings may 

result in severe eye damage and electrical 

shock.

WARNING!

 - This unit must be installed 

by a licensed HVAC contractor. Failure to 

do so will void warranty of the product.

WARNING!

 - To prevent damage 

to the unit, operating environment 

temperature must never  exceed 120˚F.

WARNING!

 - This unit must never be 

used with an extension cord.

RECOMMENDED INSTALLATION TOOLS

3 1/2” Hole Saw

for wood or metal 

(recommended)

Drill/Power Driver

Phillips 

Screwdriver

3/8” Drill Bit 

(if installing into fiberglass 

ducting with toggle bolts)

You may also need:

Utility Knife

Tin Snips 

(for metal ductwork)

11/32” Open-

End Wrench

1/4

1/4” Nut Driver 

Bit

CAUTION: When the unit is 

installed in a roof mounted 

HVAC system, the unit must be 

protected from the elements.

Dust Mask

PRODUCT CONTENTS

Power

Cord

WARNING!

 - Do not connect this unit 

to any voltage source above 32 volts.  

Doing so will cause damage  to the unit.

  ActivePure® Cell

  Item # US70678

Summary of Contents for INDUCT 2000LV

Page 1: ...r proper procedures and operation PAID ENDORSEMENT activTek Environmental 300 East Valley Dr Bristol VA 24201 www activTek net ASP_BL_62 00000_VA 00000_0312 HG LAMP CONTAINS MERCURY Manage in accordance with disposal laws www lamprecycle org activTek INDUCT 2000 LV 24 volt Item 00000000 RESIDENTIAL HVAC AIR PURIFICATION SYSTEM INDUCT 2000LV ...

Page 2: ...anging the Ballast 14 Features Ozone Production 0 02 ppm maximum with standard replaceable ActivePure Cell 0 00 ppm with ozone free replaceable ActivePure Cell Electrical 18 32VAC 50 60Hz Current 1 0A Power Factor 0 99 Power 18 Watts Mechanical Distribution via air handler Dimensions 8 5 x 8 5 x 11 21 59cm x 21 59cm x27 94cm Weight 3 pounds 1 2 kg Operating Temperature 32 120 F Coverage Up to 2000...

Page 3: ...Metal Ductwork Min 10 x 10 Fiberglass Ductwork Max 15 ft 4 METAL DUCTWORK INSTALLATION 1 1 Locate suitable area of duct for installation 3 3 Mark location for 3 5 opening using either the mounting plate or included template 4 4 Cut hole in duct using 3 5 hole saw 2 2 Cut away insulation to expose metal duct if needed a a Using template mark 4 Cutting Method holes on duct b b Drill 4 holes where ma...

Page 4: ...es using a utility knife Continue with 4 above ALTERNATIVE CUTTING METHOD FIBERGLASS DUCTWORK INSTALLATION 1 2 2 Mark location for 3 5 opening using either the mounting plate or included template Also mark the locations of 4 screw holes in corners see template 3 Cut hole in duct using 3 5 hole saw 4 Drill 4 holes at corner screw locations using a 3 8 drill bit 1 Locate suitable area of duct for in...

Page 5: ...vTek CELL HOLE PLACEMENT TEMPLATE 8 9 MARK FOR FIBERGLASS DUCT INSTALLATION MARK CENTER FOR 3 5 HOLE SAW MARK IF USING ALTERNATIVE CUTTING METHOD MARK IF USING ALTERNATIVE CUTTING METHOD MARK FOR FIBERGLASS DUCT INSTALLATION ...

Page 6: ...ation of a separate 24 VAC transformer is recommended Do not connect this unit to any voltage source above 32 volts Doing so will cause damage to the unit 5 6 7 7 Insert 4 toggle bolts into 3 8 holes in duct Be sure toggle anchors open after inserting 8 8 Center large opening in mounting plate over 3 5 opening in duct and press plate to duct The adhesive gasket will hold the mounting plate into pl...

Page 7: ...d a defect in workmanship or material These warranties do not apply for loss or damage caused by accident fire abuse misuse improper installation leaking modification misapplication or by any repairs other than those provided by our authorized Service Center This warranty is non transferable MISSING SERIAL NUMBERS AND UNAUTHORIZED CHANNELS If a valid serial number is missing from the product the w...

Page 8: ...iginal location and secure using the two 2 nuts removed in step 4 14 77 Replace cover and secure with the original four 4 screws 8 8 Re install unit if removed from duct Reconnect power cord turn breaker or fuse power back on and check for proper operation LED indicator should be lit when in operation LED INDICATOR 66 To reconnect wiring insert wire into wire pocket in ballast until bottomed Gentl...

Page 9: ...ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the eq...

Page 10: ...cellule non génératrice d ozone ActivePure remplaçable Branchements électriques 18 32VAC 50 60Hz Courant 1 0A Facteur de puissance 0 99 Puissance 18 Watts Mécanique Distribution via un système de traitement d air Dimensions 8 5 x 8 5 x 11 21 59cm x 21 59cm x 27 94cm Poids 3 livres 1 2 kg Température de fonctionnement 32 120 F Portée jusqu à 2000 pi2 186 m2 Garantie Garantie limitée de 3 ans C A R ...

Page 11: ... min Max 15 pieds 4 5 m 4 INSTALLATION DES CONDUITS MÉTALLIQUES 1 1 Repérez une zone qui convienne à l installation d un conduit 3 3 Marquez l emplacement d une ouverture de 3 5 à l aide de la plaque de montage ou du modèle inclus 4 4 Coupez un orifice dans le conduit à l aide d une scie cylindrique 3 5 2 2 Découpez l isolant afin d exposer le conduit métallique si nécessaire a a Marquez 4 orifice...

Page 12: ...z avec nº4 ci dessus MÉTHODE DE DÉCOUPE ALTERNATIVE INSTALLATION DES CONDUITS EN FIBRE DE VERRE 1 2 2 Marquez l emplacement d une ouverture de 3 5 à l aide de la plaque de montage ou du modèle inclus Marquez également les emplacements des 4 trous de vis dans les coins voir modèle 3 Coupez un orifice dans le conduit à l aide d une scie cylindrique 3 5 4 Percez 4 orifices sur les emplacements de vis...

Page 13: ...E DE PLACEMENT DE L ORIFICE DE LA CELLULE 8 9 MARK FOR FIBERGLASS DUCT INSTALLATION MARK CENTER FOR 3 5 HOLE SAW MARK IF USING ALTERNATIVE CUTTING METHOD MARK IF USING ALTERNATIVE CUTTING METHOD MARK FOR FIBERGLASS DUCT INSTALLATION ...

Page 14: ...appareil sur une prise électrique dont la tension dépasse les 32 volts Cela endommagerait l appareil 5 6 7 7 Insérez 4 boulons à ailettes dans les orifices de 3 8 du conduit Veillez à ce que les ancrages à ailettes s ouvrent après insertion 8 8 Centrez la grande ouverture de la plaque de montage sur une ouverture de 3 5 dans le conduit et appuyez la plaque sur le conduit Le joint adhésif maintiend...

Page 15: ...se application ou causés par toute réparation non effectuée par notre centre d entretien agréé Cette garantie n est pas cessible NUMÉROS DE SÉRIE MANQUANTS ET CANAUX NON AGRÉÉS Si un produit ne présente pas de numéro de série valide la garantie sera annulée Les produits activTek sont autorisés à la vente exclusivement par des distributeurs activTek Les garanties sont annulées si un produit est ach...

Page 16: ...xez le grâce aux deux 2 écrous retirés à l étape 4 14 77 Replacez le couvercle et fixez le à l aide des quatre 4 vis originales 8 8 Remettez l unité en place si retirée du conduit Rebranchez le cordon d alimentation électrique rallumez le disjoncteur ou le fusible et contrôlez le fonctionnement de l appareil l indicateur LED sera allumé lors de l utilisation INDICATEUR LED 66 Pour reconnecter le c...

Page 17: ...ences néfastes dans les environnements domestiques Cet équipement produit utilise et peut émettre de l énergie radiofréquence et s il n est pas installé et utilisé conformément aux consignes peut entrainer des interférences néfastes aux communications radio Toutefois nous ne pouvons pas garantir que des interférences ne se produiront pas dans une installation particulière Si cet équipement entrain...

Reviews: