11.
OPERATION OF IR DONGLE
Establish IR Connection with another PC after confirming the detection of IR dongle
as indicated
above. Place any other Raw IR device (e.g., ACT-). Launch your Communications
application like “HyperTerminal” or any other application in the Windows.
12.
LED BEHAVIOR
Behavior
Status
ACT-IRx24UN-Lx
ACT-IRx24UN-Lx-LE
Power on
LED
on
for one second
LED
off
for one second
Standby and receiving
LED
off
LED
on
Transmitting
Blinks rapidly but weak
13.
IR DONGLE
DIMENSIONS
ACT-IR224UN
USB Cable
Length: 120 cm
ACT-IR424UN
14.
CHARACTERISTICS AND SPECIFICATION
Parameter MIN. TYPICAL
MAX.
Units
DC supply voltage
5.0
5.2
V
Supply voltage, VSS
0
V
Operating
temperature
range
,
TA 0
60
℃
DC current (Ready mode)
15
20
mA
DC current (Active mode)
60
100
mA
Infrared Transmitting range
1
158
200
cm
USB signal threshold level
+4.8
+5V
+5.5
V