8. ELECTRICAL CHARACTERISTICS AND SPECIFICATIONS
8.1 Electrical Characteristics
Parameter Min
Typical
Max
Unit
Standby mode Current Consumption
1.640
1.650
mA
Active mode (IR link, Printing the data)
52
60
mA
DC Supply to DC Jack
4.5
7.5
12
V
Operating Temperature
0
25
60
°C
Link Distance
1
-
158
cm
IR Data rate
9600
-
115200
bps
8.2 Generic
Specifications
FUNCTION
ACT-IR100MU (IrDA SIR USB Printer Adapter)
Standard IrLPT
Interface
IrDA to USB
Configurable Parameter
No need to set any parameter
Weight
48.3 g
Dimension
8 cm X 5 cm X 3 cm