PRO-MUX-2 CONFIGURATION GUIDE
PAGE 6
The alarms are a powerful feature of the PRO-MUX-2. It allows
the user to identify various states and have a message sent by
the PRO-MUX-2 to identify what Alarm has trigged. (Message
must be enabled by ticking ‘Action: Send Message’ option for
each alarm):
• Autoswitch: PRO-MUX-2 will Autoswitch (if enabled) between
one or more inputs, and will output the following message if
Autoswitch is performed:
$MXALR,hhmmss,004,PRO-MUX-2|206221|Autoswitch
• Data Overload: PRO-MUX-2 will determine if too much data is
being sent at one time to a port, and will output the following
message if enabled:
$MXALR,hhmmss,002,PRO-MUX-2|206221|Combine: Data
overload
• Low Voltage: PRO-MUX-2 will notify if the voltage level is too
low for the device, and will output the following message:
$MXALR,hhmmss,003,PRO-MUX-2|206221|Voltage Alert: PWR
<Measured Voltage>
ALARM SETTINGS