background image

NMEA 2000 to PC Interface - NGT-1

Page 9

© 2015 Active Research Limited

NMEA 2000 Networks

NMEA 2000 devices will only communicate with each 

other when connected to a powered and correctly 

terminated NMEA 2000 network. It is not enough to simply 

connect two NMEA 2000 devices directly together.

All networks need to be powered and terminated correctly 

to allow data to be transmitted reliably on the network. 

T-Pieces are needed to connect each device to the 

network. Additional cable lengths can be used between 

any of the connectors to extend the length of the network.

Ensure the NMEA 2000 rules for cable length are adhered 

to, see 

“Table 1 - NMEA 2000 Cable Length Rules”.

Table 1 - NMEA 2000 Cable Length Rules

Cable Type

Max 

Length

Per drop cable

6m

Sum of all drop cables

72m

Micro Backbone (terminator to terminator)

100m

Mini Backbone (terminator to terminator)

200m

NMEA 2000 Minimum Network 

Requirements

All NMEA 2000 networks require a 12V DC supply.

In addition, a correctly functioning network will require the 

following components :

•  1 x Power-T

•  2 x Terminating Resistors

•  2 x T-Pieces (one per connected device)

•  2 x NMEA 2000 Devices (such as the 

NGT-1

)

All the required network parts can be supplied by the 

Actisense 

A2K

 range.

Refer to 

“Figure 2 - NMEA 2000 Minimum Network 

Requirements Diagram”

 for an example network. Note 

that the diagram should not be used as an installation 

guide. NMEA 2000 networks should only be installed 

following  the  NMEA  0400  specification  and  all  wiring 

should be in accordance with the regional code of practice 

for installations.

The 

NGT-1

 has a male Micro connector as specified by the NMEA 2000 standard. This allows the 

NGT-1

 to be connected 

directly to an NMEA 2000 bus without complication. If you are using an alternative proprietary CAN bus network, a 

suitable adapter cable will be required. It is recommended that the manual for any proprietary CAN bus network devices 

be consulted to determine the suitability of connecting an NMEA 2000 device such as the 

NGT-1

.

The NMEA 2000 drop cable on the NGT-1 is 1.5 meters long, which can be extended as required up to a maximum of 6 

meters (from the NMEA 2000 backbone), see 

“Table 1 - NMEA 2000 Cable Length Rules”

. Any drop cable extension 

should be securely connected to ensure reliable operation.

Please refer to, 

“Status LEDs” on page 13

Connecting to an NMEA 2000 Network

Power Tap

(A2K-MPT-1)

T-Peice

(A2K-T-MFF)

T-Peice

(A2K-T-MFF)

Terminator

(A2K-TER-F)

Terminator

(A2K-TER-M)

12v

Example Device

Example Device

Figure 2 - NMEA 2000 Minimum Network Requirements Diagram

Summary of Contents for NGT-1

Page 1: ...NGT 1 NMEA 2000 PC Gateway For Actisense Comms API compatible software User Manual For variant NGT 1 USB NGT 1 ISO Issue 2 01...

Page 2: ......

Page 3: ...n NMEA 2000 Network 9 NMEA 2000 Networks 9 NMEA 2000 Minimum Network Requirements 9 Figure 2 NMEA 2000 Minimum Network Requirements Diagram 9 Connecting the ISO cable 10 Table 2 ISO Cable Connections...

Page 4: ...ns 14 Minimum NMEA 2000 PGN List 15 NGT 1 Product Order Codes 16 Company information Active Research Ltd Unit 5 Wessex Trade Centre Ringwood Road Poole Dorset UK BH12 3PF Telephone 44 0 1202 746682 Em...

Page 5: ...ive Research Ltd cannot accept any liability for differences between the product and this document To check for updated information and specifications please contact Active Research Limited Active Res...

Page 6: ...he ISO PC cable Note Not to be used as wiring instructions Able to transfer all NMEA 2000 PGNs Firewall enforces NMEA 2000 bus rules Galvanic Opto isolation between the PC and the NMEA 2000 network IS...

Page 7: ...led and operated in accordance with the instructions provided Failure to do so could result in personal injury damage to your boat and or poor product performance Warning 3 Installation Code of Practi...

Page 8: ...directed to automatically search for the best driver Include Search Windows Update or ensure the Actisense CD is inserted For other operating systems and step by step guides refer to the USB Install M...

Page 9: ...network parts can be supplied by the Actisense A2K range Refer to Figure 2 NMEA 2000 Minimum Network Requirements Diagram for an example network Note that the diagram should not be used as an install...

Page 10: ...ed Actisense part DB9 F To fit the DB9 F cable refer to Connecting a Custom Cable on page 11 Note The NGT 1 ISO PCB is labelled NMEA 0183 on the RS232 side as the PCB shares the same design with the A...

Page 11: ...not 100 protected against static electricity Please ensure that you use precautions against static damage by only touching the connector block and by holding the unit by its plastic base Note Any dama...

Page 12: ...n to Transfer Receive All so that all NMEA 2000 PGNs can be transferred to the PC software application In this mode the Rx PGN Enable List is not used and any user modifications to it will not result...

Page 13: ...ed to prove the status of the NMEA 2000 network The serial LED does not flash when connected to a PC software application Check that the NGT 1 is connected correctly to the PC via USB or RS232 port an...

Page 14: ...moulded on cable Cable Length NMEA 2000 1 5m Cable Length STNG Adapter 0 4m 1 9 with NMEA 2000 cable connected PC Port ISO Variant Compatibility Full RS232 RS422 compatible Galvanic Isolation 2500V i...

Page 15: ...m the NMEA 2000 bus without limitation It is impractical to publish the entire NMEA 2000 PGN list Table 5 Minimum NMEA 2000 PGN List shows the PGN messages that cannot be disabled by software configur...

Page 16: ...SB NMEA 2000 PC Interface standard version with USB STNG A06045 SeaTalkNG to NMEA 2000 adaptor cable drop Only for purchase with Actisense NMEA 2000 devices NGT 1 Product Order Codes Active Research L...

Reviews: