63
This register sets the time, in seconds, that the modem must pause when it encoun-
ters a comma (“,”) in the dial command string.
S10
Automatic Disconnect Delay
Range:
1-254
Default:
20
Units:
0.1 seconds
This register sets the length of time, in tenths of a second, that the modem waits
before hanging up after a loss of carrier. This allows for a temporary carrier loss
without causing the local modem to disconnect. The actual interval the modem waits
before disconnecting is the value in register S10.
S11
DTMF Dialing Speed
Range:
50-150
Default:
95
Units:
0.001 seconds
This register determines the dialing speed which is prefixed for each country.
S12
Escape Guard Time
Range:
0-255
Default:
50
Units:
0.02 seconds
This register sets the value (in 20 ms increments) for the required pause after the
escape sequence (default 1s).
S14
General Bit Mapped Options Status
Indicates the status of command options. Only bit 2 and bit 5 are used, read only.
Bit 3
Result codes (Vn)
0 = Numeric (V0)
1 = Verbose (Vl) (Default)
Bit 6
Pulse dial PPS selection (&Pn)
0 = 10 PPS (&p0, &p1) (Default)
1 = 20 PPS (&p2)
Default: 8 (00001000b)