background image

 

ACTIA

 

Automotive

 

ADT001-I 

 

Headquarters  

25,   chemin de Pouvourville   -   B.P. 74215 
31432  TOULOUSE CEDEX 4  -  (FRANCE) 
 

Tél. (33) 05 61 17 61 61 - Fax : (33) 05 61 55 42 31  

Colomiers Plant 

10, avenue Edouard Serres 
Parc aéronautique – B.P. 60112 
31772 COLOMIERS cedex  -  (FRANCE) 

Tél. (33) 05 62 74 34 00 - Fax : (33) 05 62 74 34 34

 

 

TELEMATIC GATEWAY TGW2                                         

INSTALLATION GUIDE 

 
 

                          

 

 
 
 
 
 
 

Client approval: 

 

Company: 

VOLVO 3P 

Name: 

 

Date and signature: 

 

 

Classification 

Internal distribution 

External distribution 

 

Name 

Dept. 

Name 

Comp./Dept. 

 No 
 Confident. ACTIA 
 Confident. client 
  

 
 
 

 

 

 

 

 

 

By 

Date 

Sign 

 

Ref. ACTIA 

Index 

Draw 

LRoy 

 

 

TELEMATIC GATEWAY TGW2  

 

 

Verif 

NWal 

 

 

INSTALLATION GUIDE 

P212515 

Valid 

LRoy 

 

 

 

 

 

Appr 

RLeg 

 

 

© 2012 « Any reproduction of this document whether total or partial 
without the written consent of 

ACTIA

 

Automotive

 is forbidden ». 

Page  1 / 18 

Format  

A4 

Summary of Contents for TGW2

Page 1: ...34 TELEMATIC GATEWAY TGW2 INSTALLATION GUIDE Client approval Company VOLVO 3P Name Date and signature Classification Internal distribution External distribution Name Dept Name Comp Dept No Confident ACTIA Confident client By Date Sign Ref ACTIA Index Draw LRoy TELEMATIC GATEWAY TGW2 Verif NWal INSTALLATION GUIDE P212515 A Valid LRoy Appr RLeg 2012 Any reproduction of this document whether total or...

Page 2: ...ent of ACTIA Automotive is forbidden EVOLUTION TRACKING SHEET Index Concerned pages or elements Date Evolution nature and motive All 01 04 2011 Document creation A Page 1 22 05 2012 Document title modify to Telematic Gateway TGW2 installation guide Page 18 22 05 2012 WIFI access point connection procedure added ...

Page 3: ...ERVIEW 7 V INTERFACE DEFINITION 8 V 1 TGW2 PRODUCT CONNECTORS 8 V 1 1 MAIN CONNECTOR 8 V 1 2 ETHERNET CONNECTOR 9 V 1 3 USB CONNECTOR 9 V 1 4 GPS CONNECTOR 10 V 1 5 GSM2 CONNECTOR 10 V 1 6 GSM1 CONNECTOR 10 V 1 7 WLAN CONNECTOR 11 V 1 8 SIM CARD CONNECTOR 11 V 2 ANTENNA INSTALLATION 12 V 2 1 GPS and GSM antenna requirement 12 V 2 2 WLAN antenna requirement 13 VI TEST WITH LINUX APPLICATION 14 VI 1...

Page 4: ...User Manual for the Telematic Gateway TGW2 product I 2 APPLICATION DOMAIN This document is applicable for the Telematic Gateway TGW2 product I 3 DOCUMENT DESCRIPTION This document is an installation guide for the Telematic Gateway TGW2 product I 4 TYPOGRAPHIC CONVENTIONS Not applicable I 5 LOCATION OF DOCUMENT F 8000 8157 0 contractual system 5 Product Interfaces specifications 1 Product specifica...

Page 5: ...18 2012 Any reproduction of this document whether total or partial without the written consent of ACTIA Automotive is forbidden II DOCUMENTS II 1 APPLICABLE DOCUMENTS Not applicable II 2 REFERENCE DOCUMENTS Not applicable ...

Page 6: ...6 18 2012 Any reproduction of this document whether total or partial without the written consent of ACTIA Automotive is forbidden III TERMINOLOGY III 1 ABBREVIATIONS TGW2 Telematic Gateway 2 III 2 GLOSSARY Not applicable ...

Page 7: ...E quadband 850 900 1800 1900MHz optional UMTS triband 850 1900 2100Mhz GPS L1 band Optional WLAN 802 11 b g 2x CAN J1939 up to 1Mbits J1708 1587 interface Tachograph interface Digital inputs Digital outputs Ethernet interface 10 100 base T USB OTG 2 0 2x RS232 interface with one with full control signals GSM antenna 1 GSM antenna 2 GPS antenna Ethernet connector USB connector SIM card connector Ma...

Page 8: ...BUTTON_STS 27 INFO_IF 8 RI_GSM 28 CTS_GSM 9 DSR_GSM 29 RXD_GSM 10 DCD_GSM 30 RTS_GSM 11 DTR_GSM 31 TXD_GSM 12 CTRL_UBAT_V 32 GND 13 CAN1_H 33 CAN1_H_Strap 14 CAN1_L 34 CAN1_L_Strap 15 CAN2_H 35 GND 16 CAN2_L 36 CAN1_H 17 GND 37 CAN1_L 18 RS232_RXD 38 RS232_TXD 19 GND 39 GND 20 AUDIO_LINE_OUT 40 MIC Power supply The TGW2 is powered via VBAT and GND pins on the Main connetor Normale operating voltag...

Page 9: ...o be use TYCO 0 1719088 1 0 1709089 1 1719050_A 3 1418659 3 Terminals reference for plug to be use with AWG 24 20 cable TYCO 928999 1 V 1 3 USB CONNECTOR CN1005 10pins shielded black connector PIN NAME 1 USB_OTG_VBUS_CN 2 Not connected 3 Not connected 4 USB_OTG_ID_CN 5 USB_OTG_GND_CN 6 Not connected 7 Not connected 8 USB_OTG_DM_CN 9 USB_OTG_DP_CN 10 Not connected Connector reference TYCO 1 1418656...

Page 10: ...GSM2 CONNECTOR CN1003 curry fakra connector PIN NAME 1 GSM_ANTENNA_2 center pin 2 GND Connector reference IMSC 4408 SMBA 1K10 009 coding K curry Plug reference to be use all fakra plug coding K curry with max connector housing width of 11mm V 1 6 GSM1 CONNECTOR CN1001 bordeaux fakra connector PIN NAME 1 GSM_ANTENNA_1 center pin 2 GND Connector reference IMSC 4408 SMBA 1D10 009 coding D bordeaux Pl...

Page 11: ...housing width of 11mm V 1 8 SIM CARD CONNECTOR CN13003 SIM card connector PIN NAME 1 SIM_CARD_VCC 2 SIM_CARD_RST 3 SIM_CARD_CLK 4 GND 5 Not connected 6 SIM_CARD_RST SIM card connector reference MOLEX 91228 0001 SIM card drawer reference MOLEX 91236 0001 SIM card operation Interface only compatible with 3V SIM card Place the SIM card in the SIM card drawer terminal visible see picture Place the SIM...

Page 12: ...0 1910 MHz RX 1930 1990 MHz WCDMA B1 2100 TX 1920 1980 MHz RX 2110 2170 MHz Antenna impedance 50Ω DC resistance needed for antenna detection 50kΩ 20 Antenna VSWR 2 5 1 in free space for all bands Free space antenna efficiency should be greater than 7 dB 20 Combined cable loss and antenna gain o 900 MHz GSM band The combined cable loss and antenna gain must not exceed 2 65 dBi o 1800 MHz DCS band T...

Page 13: ...tomotive is forbidden V 2 2 WLAN antenna requirement The WLAN antenna shall meet the following requirement Must be compliant to WLAN 802 11 b g modes 2 4GHz IMS band Antenna impedance 50Ω DC resistance needed for antenna detection 50kΩ 20 Prefered antenna to be use for TGW2 with WLAN option Volvo WLAN antenna reference 21399362 ...

Page 14: ...gw2 gf3ac984 dirty VI 1 TGW2 POWER SUPPLY INTERFACE In order to power supply the TGW2 use a DC power supply with the following settings DC voltage shall be set to 12V normal TGW2 power supply operating range is between 10 and 36V Current consumption The DC power supply shall be able to deliver at least 1A Connect the Main truck interface to the power supply using the dedicated cable Black plug sha...

Page 15: ... cable to the PC RS232 port VI 2 2 PC RS232 port configuration Open an Hyperterminal console via the windows system Start menu Programs Accessories Communications HyperTerminal Configure the PC HyperTerminal with the following parameters Name of the console TGW for instance Select the PC RS232 port COMx which is connected the TGW Configure the properties of COMx with the following parameters o Spe...

Page 16: ...ogin shall be displayed You must enter the default login which is root and then press Return key Then the following prompt shall be displayed root root You can navigate in the different files using the Linux commands If you don t know the Linux commands you can see the general commands via typing busybox To have more help on a specific command for instance tftp type tftp help The TGW2 can be used ...

Page 17: ...W2 product variant 3G with Motorola H24 GSM module root root minicom ACM0 enter in communication with G24 Motorola GSM modem via AT command interface Then type the AT commands according to your need see below the basic AT commands Basic AT commands for more details see Motorola G24 or H24 Developer s Guide AT Commands Reference Manuals AT command Description AT CPIN Provide the SIM card PIN code s...

Page 18: ...ed by region settings where rate_index is 0 1 2 3 4 5 6 7 8 9 10 11 12 13 for 1M 2M 5 5M 11M 22M 6M 9M 12M 18M 24M 36M 48M 54M 72M where chip_ID is 8381 or 8385 OR 8686 Example txcont_new sh 1 0 8385 channel 1 1Mbps 8385 chip To turn off use 0 for channel e g txcont_new sh 0 0 8385 rate_index is ignored The TGW2 WLAN chip_ID is 8686 For instance to set the TGW2 WLAN to channel 1 rate index 12 type...

Reviews: