www.acti.com
TCM-3011 Hardware User’s Manual
10
Step 2:
Press and continue to hold the Reset Button (with a sharp tipped object, like a pen.)
Step 3:
Reconnect the power cable while continuing to hold the reset button.
The red
Power LED light will flash on for 3 second first, turn off for about 15 seconds, flash on for another
second and turn off again. By this time the reset to default operation is already completed.
This
will take around 20 seconds from power up.
You may then release the reset button. This
length of time fluctuates slightly with the environment. The Power LED light will come back on
and stay on after a few more seconds. The unit will start up with factory default settings
automatically.
On (3s)
On
1s
Power On
About 20 Seconds
Stay On
Off (about 15s)
Off (10~15s)
Restore to Default
Complete
4) DIO and Audio Input / Output
The IP device supports Digital Input / Output and Audio input / output with terminal block
connections. Pushing down the tab above will reveal a small slot for you to insert the end of wire.
Release the tab and the wire will be fastened by the internal spring. The connection pins are as
shown in this image: