background image

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face Recognition Reader 
User

’s Manual 

 

R71CF-31, R71CF-32, R71CF-33, R71CF-34 

 

 

 

 

 

2019/09/23 

 

 

 

 

 

 

 

Summary of Contents for R71CF-31

Page 1: ...Face Recognition Reader User s Manual R71CF 31 R71CF 32 R71CF 33 R71CF 34 2019 09 23...

Page 2: ...talling with Gang Box 9 Terminal Connection 12 2 Device Activation 14 3 Basic Operation 15 Application Mode Settings 15 Login 16 General Parameters Settings 17 Communication Settings 17 System Setting...

Page 3: ...www acti com User s Manual 3 Tips for Installation Environment 29 Relationship Between Wake Up Distance and Environment 30...

Page 4: ...you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Trademarks All names used in this manual are probably registered trademarks of respective companies Liabili...

Page 5: ...nstalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Page 6: ...recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info 2006 6...

Page 7: ...by unauthorized repair or maintenance Cautions Do not drop the device or subject it to physical shock and do not expose it to high electromagnetism radiation Avoid the equipment installation on vibrat...

Page 8: ...h the same or equivalent type only Dispose of used batteries according to the instructions provided by the battery manufacturer Biometric recognition products are not 100 applicable to anti spoofing e...

Page 9: ...If installing the device indoors the device should be at least 2 meters away from the light and at least 3 meters away from the window or the door If installing the device outdoors you should apply si...

Page 10: ...e the mounting plate on the gang box And use another four 4 supplied screws to secure the mounting plate on the wall 4 Route the cables through the cable hole of the mounting plate and connect to the...

Page 11: ...e mounting plate are in the holes at the back of the device 6 Secure the device and the mounting plate NOTE The recommended installation height 1 4 meters from the ground is a reference point You can...

Page 12: ...cess controller the face recognition terminal can transmit the authentication information to the access controller and the access controller can judge whether to open the door or not NOTES If you use...

Page 13: ...cti com User s Manual 13 You can also connect the device with a secure door control unit See wiring diagram is below NOTE The secure door control unit should connect to an external power supply separa...

Page 14: ...a password 2 Tap the Confirm field and input the password again 3 Tap Next and the device will be activated NOTE STRONG PASSWORD RECOMMENDED It is highly recommended to create strong password of your...

Page 15: ...s control parameters set system parameters manage data manage log query set time import and output data maintain data and view device information Application Mode Settings Select the application mode...

Page 16: ...page 2 Tap the Password field and input the device activation password NOTE The Password here is the activation password 3 Tap OK to enter the home page NOTES The device will be locked for 30 minutes...

Page 17: ...parameters includingtheIPaddress thesubnetmask andthe gateway 1 On the Communication Settings page tap Network to enter the Network tab 2 Configure the network parameters including IP Address Subnet M...

Page 18: ...an IP mode If selecting Static you should input the Wi Fi password IP address subnet mask and gateway If selecting Dynamic you should input the Wi Fi password NOTE Numbers upper case letters lower ca...

Page 19: ...ic Parameters You can set the community No building No the unit No voice prompt voice volume application mode wake up distance IR light brightness and white light brightness Parameter Description Comm...

Page 20: ...ice Note RefertoAppendixDRelationshipBetweenWake up Distanceand Environment to view the relationship between the wake up distance and the environment IR Light Brightness Set the IR light brightness wh...

Page 21: ...ed on the device screen DST Enable or disable the DST function If enabling the DST function you can set the DST start time end time and the bias time Start Time Set the DST start time End Time Set the...

Page 22: ...you can add users including the employee number name card number You can also link the face picture to the user or set password authentication mode schedule template administrator permission for the...

Page 23: ...sword NOTES The Card No cannot be empty Up to 20 characters are allowed in the Card No The Card No cannot be duplicated 6 Tap the Face Picture field to enter the face picture adding page Follow the st...

Page 24: ...the configured authenticaion mode By default the authentication mode Device This mode is applicable to edit users authenticaiton modes in batch Custom If an user needs to use a special authentication...

Page 25: ...d on the list Editing User You can edit the added user information by following the steps in this section 1 In the User Management page tap the user that needs to be edited to enter the Edit User page...

Page 26: ...ry Restore the system to the factory settings The device will reboot after thesetting Restore to Default Restore thesystemtothedefault settings The system willsave the communication settings and the r...

Page 27: ...www acti com User s Manual 27 Appendix Tips When Collecting Comparing Face Picture Position Recommended Distance 0 5 m The position when collecting or comparing face picture is as below...

Page 28: ...asses or other accessories that can affect the facial recognition function Do not make your hair cover your eyes ears etc and heavy makeup is not allowed Posture Inordertogetagoodqualityandaccuratefac...

Page 29: ...t 2 meters away from the light and at least 3 meters away from the window or the door If installing the device outdoors you should apply silicone sealant among the cable wiring area to keep raindrops...

Page 30: ...Wall in Laboratory 0 79 m 1 32 m 3 67 m Human Body 0 47 m 1 03 m 1 65 m Window Glass 1 18 1 65 m Turn on Light at Night 1 53 2 66 m Turn on Light at Night 3 35 m Daytime Turn Fluorescent Lamp on Norm...

Page 31: ...Copyright 2019 ACTi Corporation All Rights Reserved 7F No 1 Alley 20 Lane 407 Sec 2 Ti Ding Blvd Neihu District Taipei Taiwan 114 R O C TEL 886 2 2656 2588 FAX 886 2 2656 2599 Email sales acti com...

Reviews: