www.acti.com
Hardware Manual
17
2.
Pull the network cable through the flex
conduit. Please note that the size of the
conduit and the gland is big enough to let
the RJ-45 connector pass through all the
way, you may also consider to do the
RJ-45 connector crimping after pushing the
cable through the conduit.
3.
Slide the
clamping nut
around flex conduit
some 10-20 cm away from the top. Fit the
sealing insert
(made of rubber) to the top
of the flex conduit.
4.
On the camera side, decide which of the 2
possible holes you are going to use to
connect the flex conduit. There is one hole
on the side, and one on the bottom.
Whichever you pick, remember to seal off
the other one with the metal
patch
(included in the camera set).
Example
– using the side hole
5.
Screw the
body with washer
of the
conduit gland into the camera and fix it .