ACTentry A10 Operating and Installation Instructions

0

Toggled

1

Timed

2

Timed

3

Timed

Timed

4

Timed

5

Timed

Timed

6

Timed

Timed

7

Timed

Timed

Timed

ACTentry

 

A10 Programming

Press the button followed by the programming code (initially 9999). The yellow LED will flash while
in programming mode. To exit the programming mode press button . Exit from programming mode
occurs automatically if no key is activated for 30 seconds.

Changing Codes:

(From programming mode)

Enter

0

(Change codes)

0-9,

(user number 0-9, = programming code)

000000-999999

(4 or 6 digit code – 000000 deletes user)

Default user codes: Programming = 9999(99), User 1 =1234(56), All others inactive.

Setting switched output combinations:

(From programming mode)

Enter

1

(Set Outputs)

0-9

(User number 0-9)

0-7

(Output function code)

Output Function Code

Door Output

Door 2/Output 2

Output 3

Default function code is 1 (Relay Timed) for all users. When the door is toggled open, this will be

For example, to set user 1 to toggle the door open/locked:

Enter 1(set outputs), followed by 1(user1), followed by 0(Toggled).

  (e.g   -9999-1-1-0-  )

To set user 2 to open Door 2:

Enter 1(set outputs), followed by 2(user2), followed by 2 (Door 2 timed) (e.g.   -9999-1-2-2-  )

 

Setting timers:

(From programming mode)

Enter

2

(Set Timers

0-4

(Timer number) {Buzzer sounds indicating timing… wait required period}

(Stop timing) {Buzzer stops – timer set}

Summary of Contents for ENTRY A10

Page 1: ...ACT entry A10 Operating Installation Instructions 18 00044 ...

Page 2: ...maximum Operating Temperature 10 to 50 degrees C Door Open Time 0 4 minutes Relay Contact Rating 5A 50Vac Controller Size Flush Mount 378 x 144 x 11mm Surface Mount 358 x 125 x 38mm Water Resistance Medium IP54 Ordering Information Vandal Resistant Door Entry Panel with integrated ACT 10 Digital Keypad Call Button and Speech Unit in a Surface Mount Kit Door Intercom Handset Power Supply Vandal Res...

Page 3: ...ACTentry A10 Operating and Installation Instructions 3 ACTentry A10 Schematic ...

Page 4: ... new programming code 4 digits e g Change a Programming Code to 9876 9999 0 tick 9876 4 Exit Programming Mode On the digital keypad press button The yellow LED indicator stops flashing Programming code has been exited The ACTentry A10 is now ready for normal use Test the operation of the code Note The ACTentry A10 may be returned to its factory default condition at any time by entering the program...

Page 5: ...ordance with the wiring diagram below The door entry panel is supplied with either a surface or shelteredlocation Cable Requirements For optimum speech clarity it is strongly recommended that the ACTentry A10 system is installed using twisted pair telephone cable eg type CW1308 Use one of the pairs for the R O connection between the speech unit and the telephone intercom handset Connections Core d...

Page 6: ... user Default user codes Programming 9999 99 User 1 1234 56 All others inactive Setting switched output combinations From programming mode Enter 1 Set Outputs 0 9 User number 0 9 0 7 Output function code Output Function Code Door Output Door 2 Output 2 Output 3 Default function code is 1 Relay Timed for all users When the door is toggled open this will be For example to set user 1 to toggle the do...

Page 7: ...ed as a remote keypad for an alarm system The red Keypad and green indicators are controlled by the door contact and the release button inputs Operation inputs respectively and the built in buzzer is controlled by the interlock input 35 Interlock Off When set two or more keypads may be interlocked so that only one controlled door may be open at any one time The interlock output is active whenever ...

Page 8: ...ghting response to any key being pressed or while in programming mode This option is overridden by option 32 permanent backlighting To prevent any illumination unset options 32 and 42 43 Door Ajar Off When set and the door contact has been open for longer than the time programmed Alarm into the door ajar timer the built in and external buzzers sound intermittently The buzzers may be silenced by cl...

Page 9: ...he feedback threshold Check your wiring for this fault 4 The Door Entry Panel and the Door Intercom Handset are too close together You should not be able to hear the caller without the use of the Door Intercom Handset 5 The Door Entry Panel is surrounded by reflecting walls e g a basement flat In this situation acoustic feedback may occur at lower volume levels It may be necessary to change the po...

Page 10: ...Push Door Contact Button TAMPER LK1 N C N O C RELAY DOOR 2 OMRON 5A 250V AC 5A 30VDC I RO T Z DoorIntercom Handset base of Speech Unit Volume A Adjust Volume B Adjust Call Button ACT 10 Keypad Volt Free Tamper Contacts Run O and R as twisted pair V 0V V V 0V ACTentryA10 Operating and Installation Instructions Rear View T y p i c a l A C Te n t r g u r a t i o n Energised Lock C H R O T Amaximumof4...

Page 11: ...12 AC DC N C N O C 0V Buzzer OP3 Duress OP2 Interlock OUTPUTS INPUTS 0V Interlock PB2 Push Door Contact Button TAMPER LK1 N C N O C RELAY DOOR 2 OMRON 5A 250V AC 5A 30VDC I RO T Z DoorIntercom Handset base of Speech Unit Volume A Adjust Volume B Adjust Call Button ACT 10 Keypad Volt Free Tamper Contacts Run O and R as twisted pair V 0V V V 0V Rear View T y p i c a l A C Te n t r g u r a t i o n De...

Page 12: ...y Business Centre Tallaght Dublin 24 Ireland Tel 353 1 4662570 Fax 353 1 4520427 UK Locall 0845 300 5204 Web http www accesscontrol ie E mail tech accesscontrol ie Copyright 2008 Access Control Technology Ltd User List ...

Reviews: