5
Manual mode, pressing the square "Test" button will advance testing to the next
pin.
Note: The center pin of BNC should be read on LED 2. Please refer to the diagram
below
2. As Coaxial cable has only two wires, we suggest you read
the result of the LED scan using Manual mode.
3.4 Remote Test
1. Plug one end of the tested cable to the transmitting RJ45 jack on the master unit
marked with a '1' and plug the other end into the remote terminator. If the tested cable
is installed in a patch panel or wall plate, you may use the included patch cable to
solve the connector gender problem. Please refer to Diagrams below.
2. Now, set the Auto/Manual switch to Auto mode for one-person testing.
3. Read the test results from the LED display on remote terminator.
Note: The LED display on the remote unit will scan in sequence corresponding to the
transmitting end of the master unit.