Page 1: ...ro ACTpro MIFARE Readers Installation Manual ACTpro MF 1030e Slimline Proximity Reader ACTpro MF 1040e Proximity Reader ACTpro MF 1050e PIN Proximity Reader ACTpro MF 1030PM Panel Mount Proximity Reader ...
Page 2: ...mming 9 1050e Backlight Operation 10 Power On Beep Codes 10 1030PM Connections to Controllers Doorstations 11 1030PM Mounting Diagram Instructions 12 1040e 1050e Surface Mounting Diagram 13 1030e Mounting Diagram 13 1040e 1050e Flush Mounting Diagram 14 1040e 1050e Flush Mounting to UK Pattress Box Diagram 15 Product Code Description ACTpro MIFARE 1030e MIFARE Classic Proximity reader mullion moun...
Page 3: ...ly 12Vdc 24Vdc 12Vdc 24Vdc 12Vdc 24Vdc 12Vdc 24Vdc Selectable sector serial reverse serial Yes Yes Yes Yes Current Consumption Typical 30mA 30mA 70mA 70mA Current Consumption Peak 130mA 70mA 140mA 140mA Operating Temperature 10 C 50 C 10 C 50 C 10 C 50 C 10 C 50 C Transmit Frequency 13 56MHz 13 56MHz 13 56MHz 13 56MHz Keypad No No No Yes Environmental Rating IP67 IP67 IP67 IP67 Cable Distance 100 ...
Page 4: ...ption ACT MIFARE classic readers support all ACT MIFARE cards and fobs They can be configured to read serial reverse serial or sector data from any third party MIFARE Classic card Compatible with ACT MIFARE cards and fobs Configured to read ACT Sector data Serial Number or reverse serial number Configured to read Sector data form any MIFARE Classic card Read key required Configured for Wiegand or ...
Page 5: ...lour Code The following is suggested colour coding if using CAT5 or CAT6 cabling Reader Output Colour Sense White Green Clock D1 Green Data D0 Blue 12V Orange 0V GND White Orange Red LED Brown Green LED White Brown Orange Purple Programming Sector Serial ISP Grey Unused CLOCK D1 Green SENSE White DATA D0 Blue 12V Red 0V GND Black RED LED Brown GREEN LED Yellow Orange Purple ISP Grey Unused Program...
Page 6: ...Clock Data Exit Reader Wiring SENSE White CLOCK D1 Green DATA D0 Blue 12V Red OV GND Black RED Brown GREEN Yellow BUZZER INPUT Not available on 1030e SENSE White CLOCK D1 Green DATA D0 Blue 12V Red OV GND Black RED Brown GREEN Yellow DO NOT CONNECT SENSE White cable BUZZER INPUT Not available on 1030e NB Illustrations apply to all MIFARE readers ...
Page 7: ...Black White RED Brown GREEN Yellow BUZZER INPUT Not available on 1030e SENSE Blue CLOCK D1 Green DATA D0 12V Red OV GND Black White RED Brown GREEN Yellow BUZZER INPUT Not available on 1030e IMPORTANT To put ACT readers into wiegand mode connect the SENSE on the reader to 0V GND IMPORTANT To put ACT readers into wiegand mode connect the SENSE on the reader to 0V GND PIN and DATA D0 to the SENSE PI...
Page 8: ...ble configuration To change the operation power down the reader change the Orange and Purple cable for the desired operation and re apply power Sector Reader The default sector reader operation reads a numbers encoded into Sector 1 of the MIFARE cards and fobs The ACT MIFARE readers can be programmed to read any specified sector data See section on reader re programming Serial and Reverse Serial R...
Page 9: ...ll require the following information on how the existing cards are encoded before generating the programming card Data Format Data Orientation Start and End Byte Position and Read Write Keys To re program an ACTpro MIFARE reader the programming card must be presented to the reader after power up and while the LED is Red The ACTpro MIFARE will acknowledge the re programming by playing an ascending ...
Page 10: ...mpers marked LED Buzzer Operation The Internal buzzer is activated by applying 0V to the Buzz PIN The buzzer acti vates 4 seconds after the 0V is applied and sounds continuously until the 0V is re moved External Buzzer Control not available on the ACTpro MIFARE 1030 reader Power On Beep Codes The Output Data Format and the Sector Serial Operation of the reader can be de termined by the beeps gener...
Page 11: ...s on the back of the audio entry panel 2 Place the ACTpro MIFARE panel mount reader over the four studs 3 Use the four M3 washers and nuts supplied with the product to secure the reader to the audio entry panel 4 Use the wiring diagram below to connect the reader to the controller 5 When wiring is complete place the front cover back onto the audio entry panel 6 Apply power to the controller and te...
Page 12: ...red using the link wire When the link wire is connected between LED and OFF the blue LED on the front of the reader will remain off while in standby It will turn green on access granted and red on access denied When the link wire is connected between LED and ON the blue LED on the front of the reader will remain on while in standby It will turn green on access granted and red on access denied Whit...
Page 13: ...he surface Place caps onto the unit and push firmly into place ACTpro MIFARE 1040e 1050e Surface Mount Diagram Place the reader keypad onto the surface mount collar and clip down into place Use the security screw supplied to attach the unit to the surface mount collar The surface mount collar is mounted on the wall using the fixing kit supplied in the box Security screw supplied with the unit Plac...
Page 14: ...e unit Remove spacers before mounting Place the cap onto the unit and push firmly in place Place the reader keypad onto the flush mount collar and clip down into place Use the security screw supplied to attach the unit to the flush mount collar The flush mount collar is mounted on the wall using the fixing kit supplied in the box Prepare the mounting surface to receive sub surface terminals ...
Page 15: ...r keypad onto the surface mount collar and clip down into place Use the security screw supplied to attach the unit to the flush mount collar Security screw supplied with the unit Screws Standard pattress box Place the cap onto the unit and push firmly in place Note Determine the distance between the pattress box and the mounting plate using the spacers that are labelled 1mm to 4mm A spacer of the ...
Page 16: ...ht 2016 Access Control Technology Ltd Part No 18 00106 Issue 0 Access Control Technology Ltd reserve the right to change the contents of this manual and the system it applies to without prior notice While every effort has been taken by ACT to ensure the accuracy of the information contained within this document ACT assumes no responsibility for any errors or omissions No liability is assumed for d...