12
Logic Level Hz (mV Function)
RANGE
Sensitivity
(square
wave)
5.00 Hz ~ 500.0 kHz
3 Vpeak
5.00 Hz ~ 1.000 MHz
5 Vpeak
Accuracy: 0.03%+2d
Hz (Line) @ ACV, DCV, Current
Function
Sensitivity
(Sine RMS)
Range
6V
0.4V
10Hz - 10kHz
60V
4V
10Hz - 50kHz
600V
40V
10Hz - 50kHz
1000V
400V
45Hz - 1kHz
600
A
40
A
10Hz - 10kHz
6000
A
400
A
10Hz - 10kHz
60mA
4mA
10Hz - 10kHz
600mA
40mA
10Hz - 10kHz
6A
1A
10Hz - 1kHz
10A
6A
10Hz - 1kHz
Accuracy: 0.03%+3d
Non-Contact EF-Detection
Typical Voltage
Bar-
Graph
Indication
20V (tolerance: 10V ~
36V)
-
55V (tolerance: 23V ~
83V)
- -
110V (tolerance: 59V ~
165V)
- - -
220V (tolerance:124V ~
330V)
- - - -
440V (tolerance:250V &
1000V)
- - - - -
Indication: Bar-graph segments &
audible beep tones proportional to
the field strength
Detection Frequency: 50/60Hz
Detection Antenna: Top-right Corner
Probe-Contact EF-Detection: For
more precise indication of live wires,
such as distinguishing between live
and ground connections, use the
Red (+) test probe for direct contact
measurement
All specifications are nominal and may change as design improvements occur.