5 .7 Parameter overview
Menu group Function
Input
Description
codE
3009
Password input for the access to the transmitter function menu
1903
Password input for the access to the switch function menu
1111
Password input for the access to the switch point menu
Menu group Function
Input
Description
diSP
DISPLAY – includes all parameters concerning the display
AnSi
norA
View normal
GEdA
View rotated by 180°
Unit
C
Unit °C
H
Unit °K
F
Unit °F
SPoN
NA
Display measuring value - the actual measuring value is shown in the display
SPA
Display switch value - the upper limit value of the switch point 1 is shown in the display
dEA
don
Display indication on – measurement value and status LED are indicated
doFF
Display indication off – measurement value and unit LED are deactivated in the run mode.
The operation, error and switch condition indicator LED are still in process.
When accessing the password input by simultaneous pushing the two operation keys +/- and >
for three seconds, the complete display is switched on again.
Menu group Function
Input
Description
SP1
Switch output 1 – includes all parameters concerning the switch output 1
SP_1
NSiG
Adjustment with applied signal – The actual applied temperature value is captured as switch
point resp. upper switch point
oSiG
Adjustment without applied signal – The actual switch point / upper switch point is shown in
the display and can now be adjusted by the operation keys +/- and >.
rSP1
NSiG
Adjustment with applied signal – The actual applied temperature value is captured as switch
back point resp. lower switch point
oSig
Adjustment without applied signal – The actual switch back point / lower switch point is shown
in the display and can now be adjusted by the operation keys +/- and >.
Fc_1
HF_1
The switch output 1 operates in hysteresis function with switch point and switch back point
FF_1
The switch output 1 operates in window function with lower and upper switch point
Func
norF
Normal function – The switch output 1 operates in hysteresis or in window function
ErrF
Error indication function – The switch output 1 operates in error indication function for the
current output. At underrun of 4mA resp. at exceedance of 20mA, the switch output 1 is
activated depending on the settings as closed-circuit or as open-circuit.
nonc
no
The switch output 1 operates in open-circuit principle resp. – no normally open
nc
The switch output 1 operates in closed-circuit principle resp. – nc normally closed
dSP1
Switch delay time for switch point / upper switch point of switching output 1.
The switching output 1 is only activated, if after the entrance of the switch condition and after
the set switch delay time the temperature signal already fulfills the switch conditions. By this
e.g. temperature fluctuations can be eliminated.
The adjustment range is 0...99 seconds, in steps of 0,1 seconds
drP1
Switch delay time for switch back point / lower switch point of switching output 1.
The switch output 1 is only activated, if after the entrance of the switch back condition
and after the set switch delay time the temperature signal already fulfills the switch back
conditions. By this e.g. temperature fluctuations can be eliminated.
The adjustment range is 0...99 seconds, in steps of 0,1 seconds
SiN1
AuS1
Simulation – the switch output 1 is deactivated
Ein1
Simulation – the switch output 1 is activated