ACS Fluxicont FP Manual Download Page 1

03.14

Short manual

Main features

For flow velocities from 3 to 300 cm/s

Process temperature range from – 30 °C to +110 °C

Process pressure range from –1 bar to 100 bar

Integrated evaluation electronic

• 

Direct voltage with PNP switch output

• 

Universal voltage with relay output

LED bar graph for flow indication

Enclosure rotatable for optimal operability in each 

installation position

Hygienic optimized design with closed operation surface

Fluxicont FP 

Flow monitor 

Monitoring of flows

in liquids

 

Summary of Contents for Fluxicont FP

Page 1: ...1 bar to 100 bar Integrated evaluation electronic Direct voltage with PNP switch output Universal voltage with relay output LED bar graph for flow indication Enclosure rotatable for optimal operabilit...

Page 2: ...us The actual technical manual includes instructions for installation electrical connection and inauguration as well as the technical data of the device Modifications that answer the purpose of the te...

Page 3: ...ndex Application 4 Function 4 Safety notes 5 Installation 6 Process and environmental temperature 6 Installation notes 6 Installation place 6 Electrical connection 9 Potential equalization earthing 9...

Page 4: ...l The device measures the flow of a liquid medium with the calorimetric measurement method The calorimetric measuring principle is based on cooling a heated temperature sensor Heat is removed from the...

Page 5: ...ce must be chosen resp checked for compatibility with the respective application requirements contacting materials process temperature An unsuitable material can lead to damage abnormal behavior or de...

Page 6: ...treme system or medium temperatures there could exist serious dangers The screw in of the thread process connection by using the terminal housing the connection plug resp the connection cable is not p...

Page 7: ...l pipes Installation in the ascending pipeline for vertical pipes In hygienic applications installation with minimum 3 inclination because of self draining Conditionally recommended orientation Instal...

Page 8: ...pipes open towards the end The sensor tip should never touch the pipe wall Disturbance influence in the pipe system The sensor requires a fully developed flow profile for correct monitoring For this r...

Page 9: ...ion cable For the connection only suitable cables may be used that fulfills the requirements e g regarding temperature chemical resistance or laying at the place of installation Use only shielded sign...

Page 10: ...le free operation In the case of failure or at wire break both electronic switches are opened By using a two channel evaluation besides the flow monitoring also a function dependent monitoring of the...

Page 11: ...scheme Version type GA Conductor color standard connection cable M12 BN brown WH white BU blue BK black The connection cable in not enclosed in the delivery contents Version type WB Conductor color st...

Page 12: ...anufacturer If the device must be sent back for repair the following informations must be enclosed An exact description of the application The chemical and physical characteristics of the product A sh...

Page 13: ...Y others Material process connection probe process wetted V Steel 1 4404 316L resp 1 4571 316Ti Sensor length L1 mm 0 Process connection type 0 2 G 30 mm Process connection type 3 G 28 mm Process con...

Page 14: ......