Protocol Data Structure for Protocol T=0 (
dwLength=00000005h
)
Offset
Field
Size
Value
Description
10
bmFindexDindex
1
B7-4 – FI – Index into the table 7 in
ISO/IEC 7816-3:1997 selecting a
clock rate conversion factor.
B3-0 – DI – Index into the table 8 in
ISO/IEC 7816-3:1997 selecting a
baud rate conversion factor.
11
bmTCCKST0
1
B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for
direct, b1=1 for inverse)
Note: The CCID ignores this bit.
12
bGuardTimeT0
1
Extra Guardtime between two
characters. Add 0 to 254 etu to the
normal guardtime of 12 etu. FFh is
the same as 00h.
13
bWaitingIntegerT0
1
WI for T=0 used to define WWT
14
bClockStop
1
ICC Clock Stop Support
00h = Stopping the Clock is not
allowed
01h = Stop with Clock signal Low
02h = Stop with Clock signal High
03h = Stop with Clock either High or
Low
Protocol Data Structure for Protocol T=1 (
dwLength=00000007h
)
Offset
Field
Size
Value
Description
10
bmFindexDindex
1
B7-4 – FI – Index into the table 7 in
ISO/IEC 7816-3:1997 selecting a clock
rate conversion factor.
B3-0 – DI – Index into the table 8 in
ISO/IEC 7816-3:1997 selecting a baud
rate conversion factor.
11
BmTCCKST1
1
B7-2 – 000100b
B0 – Checksum type (b0=0 for LRC, b0=1
for CRC)
B1 – Convention used (b1=0 for direct,
b1=1 for inverse)
Note: The CCID ignores this bit.
12
BGuardTimeT1
1
Extra Guardtime (0 to 254 etu between
two characters). If value is FFh, then
guardtime is reduced by 1 etu.
13
BwaitingIntegerT1
1
B7-4 = BWI values 0-9 valid
B3-0 = CWI values 0-Fh valid