AND-DNV3N2
User Manual
Acrosser Technology Co., Ltd.
www.acrosser.com
Networking Desktop
Intel
®
Denverton
SoC
4GbE Copper (2-pair bypass)
2GbE Copper (or Fibber)
Page 1: ...AND DNV3N2 User Manual Acrosser Technology Co Ltd www acrosser com AND DNV3N2 Networking Desktop Intel Denverton SoC 4GbE Copper 2 pair bypass 2GbE Copper or Fibber...
Page 2: ...arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages Copyright This document contains proprietary information protected by copyri...
Page 3: ...nced Setup Hardware Monitor 28 3 2 7 Advanced Setup LAN Bypass Configuration 29 3 2 8 Advanced Setup Power Management 30 3 2 9 Advanced Setup Digital IO Port Configuration 31 3 3 Security Setup 32 3 4...
Page 4: ...3N2 4 Acrosser Technology Co Ltd 4 3 2 Watchdog 40 4 3 3 LAN Bypass Subsystem 40 4 3 4 Notes 41 5 FAQ 42 Q 1 Where is the serial number located on my system 42 Q 2 Why does the system booting take so...
Page 5: ...N function IEEE 802 11 a b g n ac and 4G LTE feature as well 1 1 Specifications Specifications are subject to change without notice System Thermal Solution PWM Smart Cooling Fans CPU Intel Denverton C...
Page 6: ...0 Power Input 12VDC 40W Adapter Software OS Support Linux Kernel 4 8 above 64 bit Mechanical Environment Dimension 220 L x 105 W x 44 H mm Operating Temperature 0 40 C 32 104 F Storage Temperature 20...
Page 7: ...Package Contents Check if the following items are included in the package Item Q ty AND DNV3N2 04PC or AND DNV3N2 04PF 1 Driver CD 1 Console Cable 1 40W Power Adapter 1 Power Cord 1 Screw Pack 1 SATA...
Page 8: ...AND DNV3N2 8 Acrosser Technology Co Ltd 1 3 System Dissection 1 3 1 Dimensions Unit mm AND DNV3N2 04PC...
Page 9: ...AND DNV3N2 9 www acrosser com AND DNV3N2 04PF...
Page 10: ...Technology Co Ltd 1 3 2 Front I O Panel ANT1 ANT2 SMA Antenna Hole Reserved for optional Wi Fi BT 4G LTE antenna LED1 6 LAN1 6 Link Active LED BP1 BP2 LAN Bypass LED HDD Storage Active LED STATUS Sta...
Page 11: ...ANT3 ANT4 SMA Antenna Hole Reserved for optional Wi Fi BT 4G LTE antenna POWER Power Button LAN1 LAN2 RJ45 LAN Port AND DNV3N2 04PC SFP1 SFP2 SFP LAN Port AND DNV3N2 04PF LAN3 LAN6 RJ45 LAN Port with...
Page 12: ...NV3N2 12 Acrosser Technology Co Ltd 2 Components Assembly Please follow the instruction to install the inner modules Step 1 Loosen the screw that lock the top cover plate Step 2 Remove the top cover p...
Page 13: ...AND DNV3N2 13 www acrosser com Step 3 Disonnect the FAN power connector Step 4 Loosen the screw that lock the inner bracket Step 5 Take out the whole module including the bracket and mainboard...
Page 14: ...AND DNV3N2 14 Acrosser Technology Co Ltd Step 6 Loosen the mainboard screws Step 7 Flip over the mainboard Identify the memory slot Step 8 Install the memory module...
Page 15: ...AND DNV3N2 15 www acrosser com Step 9 Now ready to install your hard disk Step 10 Put in the yellow washer between hard disk and holder Step 11 Screw in to hold the hard disk into position...
Page 16: ...AND DNV3N2 16 Acrosser Technology Co Ltd Step 12 Install and fasten your WiFi module with screw Step 13 Connect the WiFi RF cable Step 14 Lock the mainboard to bracket with screws...
Page 17: ...AND DNV3N2 17 www acrosser com Step 15 Install the WiFi RF cable to the ANT3 hole on chassis Step 16 Install the WiFi RF cable to the ANT4 hole on chassis...
Page 18: ...NV3N2 18 Acrosser Technology Co Ltd Step 17 Insert the mainboard together with bracket into the chassis Step 18 Install and fasten your 4G module with screw Step 19 Connect the 4G RF cable to the 4G m...
Page 19: ...AND DNV3N2 19 www acrosser com Step 20 Connect the FAN power and SATA cable Step 21 Install the WiFi RF cable to the ANT1 and ANT2 hole on top cover plate...
Page 20: ...AND DNV3N2 20 Acrosser Technology Co Ltd Step 22 Put back the top cover plate into position Step 23 Lock the bottom cover plate with screws...
Page 21: ...AND DNV3N2 21 www acrosser com Step 24 Install the bracket ears at both side of the bezel with 5 screws 2 screws at the right side 3 screws at the left side...
Page 22: ...n arrow key to highlight the option and then press the Enter key to select the item and configure the functions Version 2 19 1266 Copyright C 2018 American Megatrends Inc Select Screen Select Item Ent...
Page 23: ...1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Aptio Setup Utility Copyright C 2018 American Megatrends Inc Main Advanced Security Boot Save Exit IntelRCSetup Case Open...
Page 24: ...l and INT1A interface will not be available Enabled SHA 1 SHA256 SHA 1 SHA256 None Enabled Enabled Enabled TCG_2 1 3 TIS Auto Security Device Sup Enables or Disables BIOS support for security device O...
Page 25: ...nc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Aptio Setup Utility Copyright C 2018 American Megatrends Inc Advance...
Page 26: ...t C 2018 American Megatrends Inc Advanced USB Configuration USB Controllers 1 XHCI USB Devices 1 Drive 1 Keyboard Legacy USB Support Enables Legacy USB support AUTO option disables legacy support if n...
Page 27: ...ht C 2018 American Megatrends Inc Advanced Mass Storage Devices Sdio Device 1 Details Bus 0 dev 1c Func 0 MMC M52516 15 6GB Mass storage device emulation type AUTO enumerates devices less than 530MB a...
Page 28: ...sic properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode 3 2 6 Advanced Setup Hardware Monitor Version 2 19 1266 Copyright C 2018 American Megatrends Inc Select Scre...
Page 29: ...rol Full Speed Temperature Temperature Limit Value of FAN Full Speed PWM Slope Slope PWM value Degree C for FAN Speed Control Range 1 15 3 2 7 Advanced Setup LAN Bypass Configuration Version 2 19 1266...
Page 30: ...2018 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Aptio Setup Utility Copyright C 2018 Amer...
Page 31: ...xit Aptio Setup Utility Copyright C 2018 American Megatrends Inc Advanced Digital IO Port Configuration DIO Port1 Output Level DIO Port2 Output Level DIO Port3 Output Level DIO Port4 Output Level DIO...
Page 32: ...Setup Set Administrator Password 3 20 Password Description If ONLY the Administrator s password is set then this only limits access to Setup and is only asked for when entering Setup If ONLY the User...
Page 33: ...ity Copyright C 2018 American Megatrends Inc Main Advanced Security Boot Save Exit IntelRCSetup Boot Configuration Quiet Boot Launch PXE ROM Boot Option Priorities Boot Option 1 Boot Option 2 Hard Dri...
Page 34: ...tio Setup Utility Copyright C 2018 American Megatrends Inc Main Advanced Security Boot Save Exit IntelRCSetup Reset the system after saving the changes Save Options Save Changes and Exit Discard Chang...
Page 35: ...or settings 3 6 1 IntelRCSetup Power Configuration Version 2 19 1266 Copyright C 2018 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Op...
Page 36: ...lies to ES2 and above 3 6 2 IntelRCSetup Server ME Configuration Version 2 19 1266 Copyright C 2018 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previou...
Page 37: ...RCSetup North Bridge Chipset Configuration Memory Information MRC Version Total Memory Memory Frequency 0 149 4 43 4096 MB DDR4 1866 MHz 3 6 4 IntelRCSetup South Bridge Chipset Configuration Version 2...
Page 38: ...the Watchdog APIs to configure and to access the Watchdog timer The Watchdog timer can be set to 1 255 seconds Setting the timer to zero disables the timer The remaining seconds of the timer to reboot...
Page 39: ...ou install environment and modprobe driver on linux 6 readme Use this utility first Please read the readme file first 4 3 API List and Descriptions 4 3 1 GPIO Syntax Get_gpi_status int pin Description...
Page 40: ...et to watchdog timer register The range is 1 255 Return Value This function returns the value of the time counter and returns it to the caller as an unsigned integer Syntax Void wdt_stop void Descript...
Page 41: ...nt action Description This function can set which pair bypass power off action Parameters pair 1 2 action 0 bypass 1 normal Return Value 0 Successful 1 fail Syntax int get_bypass_poweroff_action int p...
Page 42: ...ly Q 2 Why does the system booting take so long The first time turning on the power the larger the memory capacity is the longer the booting time will take Memory size 16G 2 It takes 3 minutes for the...
Page 43: ...Address Your Company Address Acrosser Model Name Acrosser Serial Number Describe System Configuration CPU Type Memory Size Storage Device e g HDD CF or SSD Additional Peripherals e g Graphic Card Oper...
Page 44: ...ai Ran 9th Rd Che Gong Miao Futian Dist Shenzhen China Postal 518040 TEL 86 755 83542210 FAX 86 755 83700087 Acrosser Nanjing Office 228 504 211100 Room 504 No 228 Tian Yuan East Rd Jiang Ning Dist Na...