AcroComm Programming Manual
When the biosensor is disabled, then the FIU will read anything that is placed
on the FIU, even if it is not a live finger.
6.2.22. FT
Fingerprint Reading Waiting Time
Format FT=XXX
Where X is the time in tenths of a second the terminal will wait for reading a
fingerprint from the FIU when it is registering or validating a fingerprint. This
time is counted after the badge is swiped. Default 30 (3 seconds).
6.2.23. FZ
Fingerprint Table
Format FZ=ZZZZ,LL,A
where
ZZZZ: Memory reserved to store the Fingerprint Table.
LL:
Badge Length that is stored in the Fingerprint Table.
A: Number of additional fingerprints stored per badge (Default is
0). This means that if a 0 is sent here, only 1 fingerprint will be
stored per badge. Max. is 2 for three fingerprints per badge.
When the FIU reader is used, the default will be only 1 fingerprint per badge
to store on the table. If you need to save 3 fingerprints per badge, then A
should be set to 2. This will mean that only 333 people (badges) can be
registered in the FIU reader.
When the FIU is set to store 2 or 3 fingerprints, the primary finger should be
registered first (that means the finger that you intend to use the most). When
you attempt to clock in/out, you are prompted to place a finger. The terminal
will read the finger placed once, and then it will try to find a match among all
fingers stored until a perfect match is found.
6.2.24. Hx
Transaction Printing Headers
where
Format: H1=MMMMMMMMMMMMMMMMMMMM
H2=MMMMMMMMMMMMMMMMMMMM
H3=MMMMMMMMMMMMMMMMMMMM
H4=MMMMMMMMMMMMMMMMMMMM
where
MMM..: The message to be printed as header of the transaction created.
It is 20 characters long.
The terminal concatenates the values of H1 and H3 to form a 40 character first
header and the values of H2 and H4 to form a 40 character second header for
printing.
39