Acromag ACPC4610E/CC User Manual Download Page 3

     ACPC4610E/CC User’s Manual                                 CompactPCI Bus PMC Carrier 

__________________________________________________________________ 

__________________________________________________________________________

 

Acromag, Inc.  Tel: 248-295-0310  Fax: 248-624-9234  Email:[email protected]  http://www.acromag.com 

 

2

 

IMPORTANT SAFETY CONSIDERATIONS 

You must consider the possible negative effects of power, wiring, 
component, sensor, or software failure in the design of any type of  
control or monitoring system.  This is very important where property 
loss or human life is involved.  It is important that you perform 
satisfactory overall system design and it is agreed between you and 
Acromag, that this is your responsibility. 

 

1.0 General 

Information 

 

KEY  FEATURES…………...… … … … . … … … … … . .  

SIGNAL INTERFACE PRODUCTS…………………… 

 

2.0  PREPARATION FOR USE 

 

UNPACKING AND INSPECTION...…………………... 4 
CARD CAGE CONSIDERATIONS.........…………….. 

Non-Isolation Considerations........................... 

        Rear I/O Connector……………….……………… 

CompactPCI Bus Connector.…………………... 

 

3.0

  

SERVICE AND REPAIR

 

 

SERVICE AND REPAIR ASSISTANCE...……….…... 

PRELIMINARY SERVICE PROCEDURE...………….. 

WHERE TO GET HELP………………………………… 

 

4.0  SPECIFICATIONS

 

 

PHYSICAL.................................................................. 8 
CONNECTORS………………………………………….. 8 
ENVIRONMENTAL....…….…………………………….. 8 
POWER REQUIREMENTS...………………………….. 

CompactPCI BUS COMPLIANCE……………………. 

RELIABILITY PREDICTION....................................... 

 

APPENDIX

 

 

MODEL TRANS-C4610 / TRANS-C5210..………… 

10 

MODEL 5028-432………………………………………. 

11 

MODEL 5025-288………………………………………. 

11 

 

DRAWINGS 

 

MODEL ACPC4610E…………..………………………. 

12 

MODEL ACPC4610CC.………..………………………. 

13 

4502-096 ACPC4610 BLOCK DIAGRAM…………… 

14 

MODEL TRANS-C4610 / TRANS-C5210..………… 

15 

4502-089 TRANS-C4610 SCHEMATIC……………… 

16 

4502-151 TRANS-C5210 SCHEMATIC……………… 

17 

4501-919 MODEL 5028-432…………………………… 

18 

4501-920 MODEL 5025-288…………………………… 

19 

Certificate of Volatility………………………………… 20 

Trademarks are the property of their respective owners. 

TABLE OF 
CONTENTS 

The information of this manual 
may change without notice.  
Acromag makes no warranty 
of any kind with regard to this 
material, including, but not 
limited to, the implied 
warranties of merchantability 
and fitness for a particular 
purpose.  Further, Acromag 
assumes no responsibility for 
any errors that may appear in 
this manual and makes no 
commitment to update, or 
keep current, the information 
contained in this manual.  No 
part of this manual may be 
copied or reproduced in any 
form without the prior written 
consent of Acromag, Inc. 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for ACPC4610E/CC

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...0765 South Wixom Road Fax 248 624 9234 P O BOX 437 Wixom MI 48393 7037 U S A Solutions acromag com Copyright 2008 Acromag Inc Printed in the USA Data and specifications are subject to change without n...

Page 3: ...OCEDURE 7 WHERE TO GET HELP 7 4 0 SPECIFICATIONS PHYSICAL 8 CONNECTORS 8 ENVIRONMENTAL 8 POWER REQUIREMENTS 9 CompactPCI BUS COMPLIANCE 9 RELIABILITY PREDICTION 9 APPENDIX MODEL TRANS C4610 TRANS C521...

Page 4: ...cooled frame thermo bars ejector injectors and Wedge LoksR designed to thermally conduct heat away from the Conduction Cooled PMC modules per ANSI VITA 30 1 2001 Model TRANS C4610 Transition Module T...

Page 5: ...equirements Be sure that the system power supplies are able to accommodate the power requirements of the system boards plus the installed Acromag board within the voltage tolerances specified In an ai...

Page 6: ...CPC4610E CC cannot be used in 64 bit cPCI or PXI systems as rear I O J2 is mapped to the same connector as the additional control lines for 64 bit cPCI or PXI Pin Row A Row B Row C Row D Row E Row F 1...

Page 7: ...3 INTA INTB INTC 5V INTD GND 4 IPM PWR HEAL V I 0 INTP INTS GND 5 BR A5 BR B5 RST GND GNT GND 6 REQ GND 3 3V CLK AD 31 GND 7 AD 30 AD 29 AD 28 GND AD 27 GND 8 AD 26 GND V I O AD 25 AD 24 GND 9 C BE 3...

Page 8: ...our PMC module to verify that it is correctly configured Replacement of the board with one that is known to work correctly is a good technique to isolate a faulty board If you continue to have problem...

Page 9: ...gy R Bridge Chip PCI6540 primary side Type A right angle female connector 110 contacts with upper shield Note This board is universal 3 3V or 5V signal tolerant J2 CompactPCI Rear I O PMC on CompactPC...

Page 10: ...Watts Total of all supplies per PMC standard Maximum Power for Rear Transition Modules 3 3 VDC Maximum 3 Amps Fused at 4 Amps 5 5 VDC Maximum 2 Amps Fused at 3 Amps Note Model TRANS C4610 does not us...

Page 11: ...d 0 063 inches thick Operating Temperature 40 C to 85 C Storage Temperature 55 C to 100 C Shipping Weight 0 25 pounds 0 11Kg packed Type Transition module for ACPC4610 boards Same as TRANS C4610 excep...

Page 12: ...um at 50 energized SCSI 3 connector spec s Operating Temperature 30 C to 80 C Storage Temperature 40 C to 85 C Shipping Weight 1 0 pound 0 5Kg packed Type Termination Panel For CompactPCI Boards Appli...

Page 13: ...__ __________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 12 Model ACPC4610E J1 J2 F1...

Page 14: ...__ __________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 13 Model ACPC4610CC J1 J2 A...

Page 15: ...romag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 14 J1 J12 J11 J2 J14 Compact PCI BUS PMC CONNECTORS PMC SLOT 1 4502 096B 5 VDC 3 3 VDC ACPC4610 BLOCK DIAGR...

Page 16: ...___________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 15 Model TRANS C4610 TRANS C5210 TP1...

Page 17: ...25 A9 24 B9 23 C9 22 D9 21 E9 20 A10 19 B10 18 C10 17 D10 16 E10 15 A11 14 B11 13 C11 12 D11 11 E11 10 A12 09 B12 08 C12 07 D12 06 E12 05 A13 04 B13 03 C13 02 D13 01 E13 RJ2C RIO0_N RIO1_N RIO0_P RIO1...

Page 18: ...E8 25 A9 24 B9 23 C9 22 D9 21 E9 20 A10 19 B10 18 C10 17 D10 16 E10 15 A11 14 B11 13 C11 12 D11 11 E11 10 A12 09 B12 08 C12 07 D12 06 E12 05 A13 04 B13 03 C13 02 D13 01 E13 J2C RIO1_P RIO1_N RIO0_P RI...

Page 19: ...22 25 24 18 17 19 18 17 20 19 P2 12 15 14 13 12 15 14 8 7 9 10 8 7 9 10 3 2 5 4 2 5 4 3 P2 P1 64 66 2 METERS 61 60 59 58 54 53 56 55 49 48 51 50 43 44 46 45 39 38 41 40 33 36 35 34 28 30 29 23 22 25...

Page 20: ...____________________________ __________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 1...

Page 21: ...i e Memory of whose contents are lost when power is removed Yes No Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Type SRAM SDRAM etc Size User Modifiable Yes No Functio...

Page 22: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...