1.2

TRH Software Driver

TrendReader software uses a software driver to communicate with TRH-1000 data loggers.
The software driver takes the form of two windows.  The Status window, shown when you
contact the logger, is used to display the settings currently stored in the data logger.  The
Setup window, shown when you select Edit Setup, is used to alter the current settings and
apply the changes to the data logger.  The settings are divided into two main sections:  

Status

and 

Channels

.  Status contains information about sampling, memory and logger description.

Each channel of the logger contains information about the channel type (temperature or
relative humidity), equation, Realtime value, and calibration associated with the channel.  You
can control the level of detail that you see for the settings by clicking on the "+" and "-" buttons
at the left side to expand and collapse the nodes.

When you want to clear the logger's memory and start a new logging session with the existing
or new parameters, select Edit Setup from TrendReader.  In the Edit Logger Setup window,
make any necessary changes.  To implement your changes, you can either click on Apply or
OK.  OK will implement the changes and close the window whereas Apply will leave the
window open, thereby allowing you to make changes in other features.

1.2.1

Logger Status

When you contact the logger, the logger status is displayed.  The Status line indicates whether
the data logger is actively logging, waiting to start or dormant.  If you set up the logger with no
delay, it will immediately start logging. The status will show if the logger is actively logging,
dormant or set to start at a given time.  It will also show the status of the logger's capacity. 
The Status subsections are 

Sampling

 and 

Memory

.

1.2.1.1

Logger Sampling

The sample rate is the frequency with which a logger stores readings to memory.  The
Sampling subsection indicates what the sample rate is.  The rates available are from once
every 8 seconds to once every 34 minutes.  

To set the sample rate, click on the desired time unit and select the value from the drop-down
list as shown.  

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for ACR 01-0194

Page 1: ...Copyright 2010 ACR Systems Inc All Rights Reserved Reference Guide IMPORTANT TRH Data Loggers www com information itm com 1 800 561 8187...

Page 2: ...to these trademarks For more information regarding trademarks see the Trademark Notices section of this manual ACR Systems Inc assumes no responsibility for errors or omissions or for damages resulti...

Page 3: ...a charge for freight and Canadian Customs clearance if applicable Any replacement hardware or software will be warranted for the remainder of the original warranty period To the maximum extent permit...

Page 4: ...ifications 6 Product Approvals 7 2 TRH Software Driver 7 Logger Status 7 Logger Sampling 8 Logger Memory 10 Logger Channels 10 Channel Information 11 Channel Calibration 12 3 TRH 1000 Temperature Rela...

Page 5: ...TrendReader Standard conventions and procedures To get the most from your logger please take time to familiarize yourself with TrendReader Standard and its Reference Guide For important information on...

Page 6: ...a logger features make them a useful tool for data collection Pocket sized Solid state components no moving parts Low power microprocessor controlled circuitry 8 bit resolution readings High capacity...

Page 7: ...eadings to memory using one of two sampling methods 1 First in First out FIFO In this method the logger continues to take readings when its memory is full to make room it discards the oldest reading e...

Page 8: ...d running on your computer You can then configure your logger with various options by talking to it via the interface cable Set Sample Rate Always confirm the sample rate how often the logger saves re...

Page 9: ...r the logger consider using a protective enclosure For humid conditions you can protect your logger simply by placing it in a zip lock plastic bag Note that covering the logger may affect the relative...

Page 10: ...er channel Memory Usage 1 Continuous First in First out 2 Stop when full Fill then stop Sample Intervals User selectable rates from every 8 seconds to 34 minutes Sampling Mode 1 Average over sample in...

Page 11: ...idity in TrendReader software Specifications are subject to change without notice 1 1 7 Product Approvals Certified to CE standard EN61326 1977 A1 1998 European Emissions and Immunity covering ESD RFI...

Page 12: ...new logging session with the existing or new parameters select Edit Setup from TrendReader In the Edit Logger Setup window make any necessary changes To implement your changes you can either click on...

Page 13: ...is stored in memory and what the start and end times or capacity are for the data logging In the FIFO First In First Out mode the logger continually stores data and when the memory limit is reached th...

Page 14: ...the right This will pop up a form allowing you to set the date and time Highlight the date or time and enter the appropriate value You can also click on the drop down list arrow to bring up a calendar...

Page 15: ...ons or you can create your own custom equations See Equations in the TrendReader guide for further information To set the equation click on the Equation field and select the equation from the drop dow...

Page 16: ...ke the output more accurate To set each calibration value click on the appropriate calibration field and enter the value The factory equations for the TRH 1000 use the Low and Mid values as offset and...

Page 17: ...cables wires or accessories are required making the TRH 1000 the ideal data logger for quick and accurate temperature and humidity measurements in a variety of applications 1 3 2 Setup Once the logger...

Page 18: ...may vary dramatically from location to location Such factors as air stratification drafts and proximity to heat or humidity sources people equipment moisture solar gain etc can contribute to a wide v...

Page 19: ...fifteen readings and stores that average in its memory Otherwise if the sampling mode is set to Spot the logger still takes readings every 8 seconds but only stores the reading taken at the selected...

Page 20: ...ght 2010 ACR Systems Inc All Rights Reserved 32 sec 0 12 2 8 0 56 sec 0 21 3 44 0 2 min 0 45 8 0 0 4 min 56 sec 0 111 19 44 0 10 min 0 226 16 0 0 20 min 1 87 36 0 0 30 min 1 315 0 0 0 www com informat...

Page 21: ...Calibration 11 Channel Information 10 Channels 10 Description 1 Features 1 How to Use 3 Memory 8 Operation 2 Readings 2 Sampling 7 Setup 7 Software 7 Specifications 5 Status 7 Unknown Equation 10 TRH...

Reviews: