• The appliance can be operated manually

using the controls situated on the top right
hand side of the insert.

• On/off power switch

– this is used to turn

the mains supply to the appliance on or off.
When the switch is in the ON position, the
orange stand by indicator light will show on
the top right corner of the screen. This switch
needs to be in the ON position to operate
manually or via the remote control / app. 

• STAND BY

- Used to switch the appliance to

Standby Mode 

• FLAME

- Pressing this button will allow you

to cycle through the 4 flame settings 

• HEATER

- Press this once to select low heat

(the indicator light will glow orange), twice to
select the high heat (the indicator light will
glow red), three times to switch the heater off.
The heater will blow cold air for a number of
seconds once switched off before coming to
a stop. Please note that the heater will only
operate when the room temperature is below
the temperature indicated on the remote
control handset. This can be altered via the
handset or via the app. 

• MODE

- This allows the appliance to go

through a pre-programmed sequence of
effects. To use this, press and hold the MODE
button until it beeps (approx 4 seconds) and
the selection of pre-programmed sequences
will commence. 

• Remove the battery/control panel

cover by sliding completely down
and insert 2 x AAA batteries
ensuring these are inserted
correctly. Slide the cover back up to
the original position to refit. Old
batteries should be disposed of
responsibly at a local recycling
location. 

• Ensure that the ON/OFF power

switch on the unit is in the ON
position. 

• Aim the remote control handset

directly towards the fire and press
the function button required. 

• Sliding the door down on the

remote control will reveal more
functions. Otherwise using the
basic remote control buttons will
operate the fire in the same way as
the manual control buttons.

Controls

Manual Controls

Remote Control

ST
ANDBY

FLAME

HEA

TER

MODE

 

 

 
 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Please note batteries are not included.

2 x AAA batteries are required.

ACR 600 900 1200 install manual 16pp 1021-9  14/02/2022  18:26  Page 11

Summary of Contents for PR-1200e

Page 1: ...Thank you for purchasing an ACR Fireplace Insert T E C H N I C A L A N D U S E R M A N U A L Document ACR ELEC INSERT Version 1 Date 01 11 21 Serial Number REMOTE CONTROL ACR APP CONTROL BLACK POWDER...

Page 2: ...technical assistance in the future Prior to installation this appliance should be stored in a dry area do not store this unit outside or in damp conditions even if it is still in it s packaging Regist...

Page 3: ...can be affected by water or humidity for example a bathroom This appliance has been designed to be installed into a fireplace and as such it is not a freestanding unit and should not be used as such...

Page 4: ...complete with a UK 3 pin plug If the plug is removed for any reason it must be wired into an earthed power source Any alterations to the cable or power supply must be carried out by a competent person...

Page 5: ...gned for use ONLY as described in this manual Any other use could lead to bodily harm and or fire Thank you for purchasing an ACR Fireplace Insert Please take a few moments to read through the followi...

Page 6: ...flush up to the plastered finish see drawings below Ensure that the cable is not run across the heater and can be plugged into a mains socket without the use of an extension cable A qualified electri...

Page 7: ...e logs can then be placed in a position of your choice over the crystals Please handle the logs with care as these are delicate We suggest the following log layouts to give the best effect Model PR 60...

Page 8: ...8 Placing the Logs and Embers Model PR 900e Supplied Log Set Model PR 900e Suggested Log Layout ACR 600 900 1200 install manual 16pp 1021 9 14 02 2022 18 26 Page 8...

Page 9: ...9 Placing the Logs and Embers Model PR 1200e Supplied Log Set Model PR 1200e Suggested Log Layout ACR 600 900 1200 install manual 16pp 1021 9 14 02 2022 18 26 Page 9...

Page 10: ...ACR HEAT PRODUCTS LTD Model Number PR 600e Voltage 220V 240V AC50HZ Fuse 13 Amp Minimum Heat Output 800 Watts Maximum Heat Output 1600 Watts Product Dimensions H 650mm W 678mm D 168mm 678mm 168mm 437...

Page 11: ...n the remote control handset This can be altered via the handset or via the app MODE This allows the appliance to go through a pre programmed sequence of effects To use this press and hold the MODE bu...

Page 12: ...NG to confirm the required day The hour setting will now be blinking Adjust this by using the CLOCK UP and CLOCK DOWN to reach the present hour and confirm by pressing CLOCK SETTING The minute setting...

Page 13: ...he fire screen The red light will be blinking quickly at roughly 2 times per second When prompted by the App if the red light in blinking rapidly press NEXT Adding your device wait whilst the App adds...

Page 14: ...Serial Number Date of purchase Date of installation Dealer Name and address Warranty Claim Form In the unlikely event of a warranty claim please complete the below claim form and return it to your su...

Page 15: ...t of a service call being made and no fault being found or an installation error causing the fault this will result in a charge being made for the call out by our appointed service engineer It is the...

Page 16: ...uct from overheating and potentially causing a fire If the appliance reaches a temperature above the guideline parameters the automatic thermal cut out safety feature will activate and the heater will...

Reviews: