background image

Important!

• The installation of this appliance must

comply with current Building
Regulations and local regulations,
including those referring to national
and European standards need to be
complied with when installing the
appliance. 

• Do not operate this appliance if it

becomes damaged.

• Improper use, maintenance or fitting

parts other than those approved by
the manufacturer could lead to the
appliance becoming damaged or
unsafe which in turn could lead to
personal injury or damage to the
property and will void the warranty.

• The appliance must not be modified in

anyway unless authorised by ACR
Heat Products Ltd.

• The appliance should be inspected

regularly to ensure the airways are

clean and free from obstruction and

the chimney swept at least once a

year.

• The external surfaces of this

appliance will be very hot to the touch

when in operation and due care will

need to be taken when operating the

appliance to ensure safety. A fire

guard should be fitted if it is likely that

the elderly, infirm or children may

come into contact with the appliance. 

• This appliance must not be used as

an incinerator.

• This appliance has been designed for

intermittent operation.

To ensure that you gain the most from your purchase, please

take a few minutes to read through this manual before lighting

the appliance for the first time.

Since April 2002 only registered competent installers can install solid

fuel appliances. Installations carried out by non-registered installers

must be inspected by local authority building control. 

For more information please contact hetas at: www.hetas.co.uk or

telephone: 0845 6345626

Before installation, please ensure that the correct model has been supplied. 

Please make a note of the serial number of your appliance in the space

provided on the front cover of this manual as this will be requested if you

require technical assistance in the future.

Please also ensure that the commissioning checklist at the rear of the manual

is completed in full.

Oakdale FB1 A5 0414-1  30/04/2014  16:27  Page 2

Summary of Contents for Oakdale FB1MF

Page 1: ...r for future reference Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L Document FB1MF 0101 Version 1 Date 03 03 14 Serial Number MULTI FUEL DEFRA APPROVED AIRWASH SYSTEM 5 YEAR 5 YEAR WARRANTY Oakdale FB1 A5 0414 1 30 04 2014 16 27 Page 1 ...

Page 2: ...ance to ensure safety A fire guard should be fitted if it is likely that the elderly infirm or children may come into contact with the appliance This appliance must not be used as an incinerator This appliance has been designed for intermittent operation To ensure that you gain the most from your purchase please take a few minutes to read through this manual before lighting the appliance for the f...

Page 3: ...rmeability 5 0m h m then 550mm kW of appliance rated output If in doubt please consult your registered installer for advice Nominal heat output 5 kW Wood 5 kW Smokeless Fuel Chimney draft required 12Pa Height 550 mm Width 440 mm Depth 370 mm Weight 90 kg Air Requirement N A Flue Mass Gas Flow 3 4g s Wood 4 7g s Smokeless Fuel CO 13 O2 0 08 vol Mean Flue Gas Temperature 274 C Wood 273 C Smokeless F...

Page 4: ...uel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Oakdale FB1MF has been recommended as suitable for use in smoke control areas when burning wood as such when the secondary air slider is in the closed position it remains open by 25mm and the tertiary air control should be fully ope...

Page 5: ...s enough space should be left around the appliance to enable the heat produced to rise and escape from the recess back into the room Hearth Requirements The appliance must stand on a level fireproof hearth with a minimum thickness of 12mm The hearth temperature created by this stove is below 100 C The hearth must protrude at least 300mm in front of the appliance and 150mm either side of the applia...

Page 6: ...moke exempt stop Under no circumstances should it be tampered with or removed unless expressly authorised by a competent person and the appliance is not installed in a smoke exempt area If the appliance is to be installed in a non smoke exempt area you can remove the restricting screw on the secondary air control indicated by the two holes to allow full movement of the secondary air slider The app...

Page 7: ...e has overheated the appliance and flue will need to be inspected for any damage before it can be operated again Recommended Fuels Wood hardwood such as ash oak and beech which have been cut for at least 2 years and stored under shelter The logs should have a maximum moisture content of 20 Maximum log length 300mm maximum width 125mm Smokeless Fuels below 20 Petroleum coke content such as Anthraci...

Page 8: ...red by moving the secondary air slider marked with a double hole push the lever inwards to close down and pull outwards to increase the burn rate Care should be taken to ensure that the logs are not placed higher than the log guard allows This stove features a split log guard to allow differing loads to be managed only alter the log guard when the appliance is fully cold Instructions for use with ...

Page 9: ...n this manual should not be exceeded overloading can cause excess smoke Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in the instructions Air controls left open Operation with the air controls or appliance dampers open fully can cause damage to the appliance The appliance mus...

Page 10: ...ual basis to ensure the correct operation of this appliance The glass can be cleaned using a soft damp cloth or a ceramic glass cleaner available from your local stockist Use only replacement parts recommended by the manufacturer We recommend that the appliance is serviced annually by a competent engineer to ensure it s continued safe operation Fire difficult to Green wood wet wood Use hardwood lo...

Page 11: ...f during the first firings as the paint cures Advise the customer on the safe operation of the appliance Leave the instruction manuals operating tool and glove for the customer s use Record the flue draught reading of the appliance Please tick boxes when each procedure is completed To remove the internal vermiculite baffle Firstly remove the front fuel retaining bars Then slightly lift the baffle ...

Page 12: ...Parts Information Oakdale FB1 A5 0414 1 30 04 2014 16 27 Page 12 ...

Page 13: ...ER 34 03 22201 041 HEXAGON FLANGE BOLT M8X20 BLACK 35 03 13612 000 BUSH Ø12XØ8X3 5 36 03 18710 000 WASHER 8X25 37 04 26419 000 GLASS FIBRE ROPE Ø6MM SELF ADHESIVE 38 03 22204 041 HEXAGON FLANGE BOLT M8X35 BLACK 39 03 22202 041 HEXAGON FLANGE BOLT M8X30 BLACK 40 03 76320 000 ADJUSTBLE LEG 42 04 26422 000 GLASS FIBRE BAND 10X3MM SELF ADHESIVE 43 03 19505 000 STUD M6X35 44 03 18701 000 WASHER 6X18 45...

Page 14: ...o the following conditions The appliance must have been installed by a registered competent installer HETAS or inspected by local authority Building Control The appliance must be installed and operated in accordance with our instruction manual The guarantee is for a period of 5 years on the appliance body from the date of purchase The following components are considered as consumables and are excl...

Page 15: ...ng Control Certificate Number if not installed by a registered competent installer Dealer Name and address In the unlikely event of a warranty claim please return the above claim form to ACR Heat Products Limited Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Oakdale FB1 A5 0414...

Page 16: ...imited Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Oakdale FB1 A5 0414 1 30 04 2014 16 28 Page 16 ...

Reviews: