background image

Y1-03-0232F

 

The  URC-300  Master  Controller  has  a  searchlight  motor  time-out 
feature. 

If  a  Point  Pad™  rotation  switch  (right  or  left)  is  continually 

engaged  for  more  than  50  seconds,  the  Master  Controller  will  interrupt 
the operation until the Point Pad switch is disengaged. This feature will 
save  the  searchlight  motor  from  burnout  due  to  accidental  activation. 
The  elevation  motor  has  similar  features  which  will  timeout  in 
approximately 20 seconds. 
 

XRCiZ

™ feature  

The  URC-300 

Master  Controller  has  the  unique  XRCiZ™  feature.  The 

XRCiZ™ feature routinely operates all moving parts of the searchlight to 
keep  the  motors  and  drive  mechanism  freely  running.  Once  activated, 
and  every  30  days  thereafter,  the  XRCiZ™  feature  wakes  up  and 
operates  the  searchlight.  The  searchlight  will  rotate  360

°

  in  both 

directions and the parabolic reflectors will move to the full up and down 
positions. This feature keeps the searchlight in peak working order when 
not in service for long periods of time.  
 
To  activate  the  XRCiZ™  feature,  press  and  hold  the  Point  Pad™ 
ON/OFF button for greater than 5 seconds. The green LED on the URP-
102 Point Pad™ indicates that the XRCiZ™ feature is enabled.  
 
While  the  XRCiZ™  feature  is  operating  the  searchlight,  pressing  any 
Point Pad™ button will stop the XRCiZ™ command. 
 
To  deactivate  the  XRCiZ™  feature,  press  and  hold  the  Point  Pad 
ON/OFF  button  for  greater  than  5  seconds.  The  red  LED  on  the  URP-
102 Point Pad™ indicates that the XRCiZ™ feature is disabled. 
 

NOTE: 

The 

Searchlight  should  not  be  covered  while  the  XRCiZ™ 

feature is enabled.

 

 

Self- Park feature 

The  URC-300  Master  Controller  has  a  Self-  Park  feature.  When  the 
Self-Park feature is activated, it  will automatically return the searchlight 
to the forward (or aft, if mounted as such) position when the searchlight 
lamps are turned off. The feature also works with the XRCiZ™ function 
to return the searchlight to it Self-Park position.  
 

SECTION 6 - 

POINT PAD™ OPERATION 

 

Press the On/OFF button to turn the lights ON or OFF. 
 

 

Press  the  SPEED  button  to  toggle  between  High  and  low  rotation 
speeds. 
 

 

Press  the  Right  or  Left  arrows  to  rotate  the  searchlight  in  the 
direction. 
 

Summary of Contents for COBHAM RCL-300A

Page 1: ...PRODUCT SUPPORT MANUAL RCL 300A Searchlight Remote Control System Model No RCL 300A Product No 1933 Y1 03 0232 Rev F...

Page 2: ...mpany has four divisions that collectively specialize in the provision of components subsystems and services that keep people safe improve communications and enhance the capability of aerospace and de...

Page 3: ...__________________________ 5 SECTION 5 URC 300 MASTER CONTROLLER _____________________ 7 SECTION 6 POINT PAD OPERATION __________________________ 9 APPENDIX A SPECIFICATIONS __________________________...

Page 4: ...ver 500K candela CD each and 1 million effective CD when combined All functions of the searchlight can be electrically operated by remote control from the pilot area or the vessel using the URP 102 Po...

Page 5: ...ing hardware and the base of the searchlight Be sure these washers have been inserted in the base mounting holes and that the mounting base gasket is securely in place before bolting down Apply silico...

Page 6: ...er and the URP 102 Point Pad This system is compatible with 12 VDC through 24 VDC systems without modification SECTION 4 URP 102 POINT PAD Case options The URP 102 Point Pad is supplied as a surface m...

Page 7: ...d Apply a sealant around the cut out to protect from moisture intrusion Connecting to the Master Controller The Point Pad communicates with the Master Controller via standard television type RG 59 coa...

Page 8: ...tion must be paid to the following chart The Master Controller is supplied with an in line fuse holder on the Orange power lead Use only 30 amp fuses in this fuse holder See chart below for the Master...

Page 9: ...ollowing the wiring scheme in Table 1 use the supplied butt connectors to connect the Master Controller to the power source Refer to Table 2 for proper wire size for connection of the input power line...

Page 10: ...long periods of time To activate the XRCiZ feature press and hold the Point Pad ON OFF button for greater than 5 seconds The green LED on the URP 102 Point Pad indicates that the XRCiZ feature is enab...

Page 11: ...k feature press and hold the Point Pad Speed button for more than 5 seconds While the Self Park feature is operating the searchlight pressing any Point Pad button will stop the park command and leave...

Page 12: ...7 per second Lamp Twin 35W metal halide lamps 1 000 hours operating life Accessories Secondary Point Pad for remote control with Install Kit ACR P N 9282 3 Replacement 35W halide lamp ACR P N 6009 Fo...

Page 13: ...02 with surface mount case 1 A3 06 2230 URC 300 Master Controller unit 1 A3 06 2231 1 Case flush mount 1 A1 18 1875 2 Gasket surface mount 1 A1 25 0140 1 Gasket flush mount 1 A1 25 0140 2 U Clamp 2 A1...

Page 14: ...Y1 03 0232F 13 APPENDIX C WIRING DIAGRAM...

Page 15: ...ND EXPRESS OR IMPLIED AS TO MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT TO THIS PRODUCT The Company shall not be liable for consequential or special damages To pl...

Page 16: ...ssions EN 60945 2002 Immunity IEC 61000 4 2 1995 Electrostatic Discharge IEC 61000 4 3 1995 Radiated Immunity IEC 61000 4 6 1996 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips...

Reviews: