FINAL FITTING
OF THE FRAME
ASSEMBLY
Due to the weight of the
frame assembly, it is recom-
mended to seek assistance
for this operation.
The frame assembly will be
supported by keyhole slots
by four M6 screws which pro-
trude from the front of the
outer casing. Ensure each
screw is unscrewed approxi-
mately one turn from the
fully screwed in position in
order to create a 2mm gap
(shown). Simply hang the
facia panel onto the outer
casing, starting with the two
bottom fixings, ensuring that
the corresponding keyhole
shaped holes engage the
screwheads fully.
BRIEFING THE
CUSTOMER
All instructions must be
handed to the user for safe-
keeping. Show the customer
how to light and control the fire.
After commissioning the appliance, the customer should be instructed on
the safe use of the appliance and the need for regular servicing. Frequency
of service depends on usage, but MUST be carried out at least once annu-
ally.
Advise that cleaning of the fire may be achieved when the fire is cold using
a clean microfibre cloth on most surfaces. See cleaning instructions. Advise
that the fire will emit a "newness" smell for a time after initial commis-
sioning and that extra ventilation may be needed during this time.
Recommend that a guard be used for the protection of the young, pets, the elderly and the infirm
SERVICING
Isolate the fire from the gas supply. Ensure that the fire is fully cold before attempting service. A sug-
gested procedure for servicing is detailed below.
7
8.4
9.0
10.0
1. Lay out the dustsheet and tools.
2. Remove the facia section. Removal is the reverse of fitting as detailed in section 8.4.
3. Remove the glass door assembly and clean carefully.
4. Inspect the burner and the catalysts and clean if necessary with a soft brush.
5. Disconnect the gas supply.
6. Undo the four screws retaining the burner support brackets to the base and rear of the firebox.
7. Remove the burner unit, strip off the burner pipes and clean thoroughly.
8. Clean the in-line restrictor, pilot assembly and the burner tube. Do not attempt to remove the
pilot injector as this can cause damage.
9. Re-assemble components.
10. Turn on the gas supply and check tightness. Check pilot and burner for good ignition.
11. Refit the glass door assembly, ensuring a good seal.
12. Refit the facia as detailed in section 8.4.
13. Check the purpose provided ventilation is un-obstructed.
14. Light the fire and test setting pressures.
15. Check safe operation of the appliance.
For specific servicing instructions, see relevant sections.