background image

230V

12V

TRANSFORMER 

SLT-350

B

COLOUR

 

LIGHT

230V

Power

MODULATOR

RCP-1500

N

 

L1

 

L2

 

L3

 

L4

POOL

 

CONTROL

 

PANEL

230V

 

POWER

2x1mm

2

2x1mm

POOL

 

LIGHT

90 LED, 

324

 

LED

or 

531

 

LED

Connection Diagram

C

able for connecting

transformer pole

to modulator pole

Summary of Contents for RCP-1500

Page 1: ...LED pool light Remote Control OWNER S MANUAL Controls Pool Lights and 2 auxiliary circuits RCP 1500 ...

Page 2: ...ecifications Box contents Installation instructions Pairing Handheld Transmitter controller Handheld transmitter functions Replacing transmitter battery Troubleshooting Page 3 Page 4 Page 5 6 Page 7 Page 8 Page 8 Page 9 page 2 of 12 ...

Page 3: ...on rate 0 C 40 C 10 90 RH non condensing 150x157x51 mm 500 g IP54 Nominal Input voltage Max rating Relay Contacts Color Light A and B Resistive Load Inductive Load Frequency band transmitter IEC Protection Class 230 VAC 50 Hz 14A 250VAC 14A 30VDC 6A 250VAC 6A 30VDC 868 MHz Class II For operation only with 12VAC safety isolation transformer to power LED Pool Lights ...

Page 4: ...page 4 of 12 Box contents 1 2 4 5 1 RCP 1500 controller 2 Handheld transmitter 3 Spare battery type A23 12V 4 Screws 4x wall plugs 4x 5 Owners s manual 3 ...

Page 5: ...0VAC INPUT terminal Connect the primary circuit of a 12VAC transformer sold sepa rately in series with the Color Light terminal of the RCP 1500 The Color Light relay contact has an output of 14A which can drive a 12V transformer of max 3000W 220Vx14A Optional The Switch A switch B terminals can be used to control auxiliary circuits like a pool cover or garden lights RCP 1500 ...

Page 6: ...ely in series with the Color Light terminal of the RCP 1500 The Color Light relay contact has an output of 14A or 170W on a 12V transformer secondary 14Ax12V The total load of pool lights can not exceed this Optional The Switch A switch B terminals can be used to control auxiliary circuits like a pool cover or garden lights 230VAC Garden lights Pool cover 230VAC 230VAC 12VAC RCP 1500 ...

Page 7: ...inside the con troller for at least 5 seconds The LED will start to blink fast 2 Within 25 seconds press any button on the handheld transmitter If the transmitter is paired correctly the LED will flash slowly for 5 times If the RCP 1500 pairing memory is full the LED will flash 15 times This means 6 handheld devices have already been paired To unpair all handheld transmitters with the controller P...

Page 8: ... Toggle the lamps ON OFF Go to next color program Toggle Output A ON OFF Toggle Output B ON OFF Replacing transmitter battery Remove the philips head screw and open the transmitter Replace the battery respecting the polarity Battery type A23 12V ...

Page 9: ...peat the pairing process Reduce the distance between handheld transmitter and RCP 1500 and or remove obstacles The pool lights don t work Check if all connections are made according to the electri cal scheme on page 5 or 6 Check if the Color Light out put terminals of the controller switch on and of when pushing the on off button on the trans mitter Troubleshooting page 9 of 12 ...

Page 10: ... 230V Power MODULATOR RCP 1500 N L1 L2 L3 L4 POOL CONTROL PANEL 230V POWER 2x1mm 2 2 x 1 m m POOL LIGHT 90 LED 324 LED or 531 LED Connection Diagram C a b l e f o r c o n n e c t i n g t r a n s f o r m e r p o l e t o m o d u l a t o r p o l e ...

Page 11: ......

Page 12: ...ts to change all or part of the contents of this document without prior notice 15 Souri str 121 31 Peristeri Athens Greece Tel Fax 30 210 5721058 30 210 5771863 30 210 5774345 E mail info acquasource gr www acquasource gr ...