Acqua Brevetti BravoFIL Plus Installation And Operating Manual Download Page 7

MAN055 

– REV. 0   DATE: 11.01.2011      

 DRAFT BY:  U.T. 

PAG. 7 DI 9 

 

 
Acqua Brevetti 95 s.r.l. 

 

  

 

 

 

CARTRIDGE REPLACING (THIS OPERATION SHOULD BE PERFORMED BY AUTHORIZED PERSONEL ONLY)  

When the filtering cartridge must be replaced belong to the following procedure. 

Before replacing the filtering cartridge pout the filter in by pass position. Turn the green knob clockwise and place the 

filter in discharge position allowing the water to be completely drained from filter bowl. 

Note. 

Even  if the following pictures are referred to a filter not installed, the same phases can be followed in case of 

filter is mounted on line. 

 

 

 

 

1.1.

 

Remove fork in steel. 

1.2.

 

Slip off the green discharge. 

1.3.

 

Remove brass ring nut. 

 

 

 

 

1.4. 

Unscrew the bowl. 

 

1.5. 

Grasp the cartridge at the bottom, push and 
rotate upward to unhook cartridge from 
bayonet connection. Possibly help with a 
screwdriver, taking care not to damage the 
fins of closure. 

1.6. 

Replace  the  damage  cartridge  with  a 
new  one.  Put  teeth  at  the  top  of  the 
cartridge  in  the  appropriate  locations. 
Rotate  counter-clockwise  until  the 
locking of the cartridge. 

   

 

 

 

1.7. 

Turn the knob until the slits placed on the 
inside of the impeller are open and not 
closed by the rear plate.  

1.8. 

Insert  a  curved  pincer  inside  the  discharge 
valve  and  rotate  it  clockwise  to  close  the 
valve completely.  

1.9. 

Screw  the  brass  nut,  insert  the  green 
plastic  cover  and  put  in  the  fork  up  as 
the initial conditions.  

 

BravoFIL  filter,  in  particular  after  the  filtering  cartridge  replacing  or  the  discharge  valve  replacing,  may  require  the 

operation of placing in phase. 

This operation must be executed according to the following procedure (see Figures from 1.1 to 1.7). 

1.

 

(Figure 1.1) Remove fork in steel. 

2.

 

(Figure 1.2) Slip off the green discharge. 

3.

 

Remove brass ring nut. 

4.

 

(Figure  1.8)  Insert  a  curved  pincer  inside  the  discharge  valve  and  rotate  it  clockwise  to  close  the  valve 

completely.  

5.

 

(Figure 1.9) Screw the brass nut, insert the green plastic cover and put in the fork up as the initial conditions 
(see Figure 1). 

 

DISCHARGE VALVE CLEANING 

 

 

 

 

2.1. 

Discharge 

valve 

in 

opened position 

2.2. 

Discharge 

valve 

in 

closed position 

 

 

1.

 

(Figure 1.2) Remove the discharge green cover 

2.

 

(Figure 1.3) Screw off the brass fixing nut  

3.

 

(Figure 1.4) Remove the filter bowl 

4.

 

(Figures 2.1 and 2.2) Clean thoroughly the discharge valve 

keeping it in the opening and closing position alternatively 

removing dirt eventually present in the o-ring seat. 

5.

 

Replace the discharge valve in the filter bowl 

6.

 

Screw the bowl on the filter head. 

7.

 

Screw the closing brass nut 

8.

 

Insert the discharge green conveyor and place the pin. 

 

Summary of Contents for BravoFIL Plus

Page 1: ...OPERATING MANUAL SEMI AUTOMATIC SELF CLEANING FILTER WITH PRESSURE REDUCER BravoFIL Plus Semi automatic self cleaning filter with pressure reducer BravoFIL Plus Fittings Code FT120 1 FT122 1 1 4 FT12...

Page 2: ...DI 9 Acqua Brevetti 95 s r l DIMENSIONS The dimensions are in mm Filter Code A B C D E F mm FT120 180 270 105 375 400 160 FT122 175 270 105 375 400 160 FT124 185 270 105 375 400 160 Document Revision...

Page 3: ...ch as sand silt rust oxides The filter is equipped with a pressure reducer that lets you adjust the pressure downstream thereof in a range of values ranging from 1 to 6 bar The maximum diameter of par...

Page 4: ...ments installed before the filter to eliminate any foreign body It is advisable to install shut off valves immediately up stream and down stream the unity It is advisable to install a by pass valve to...

Page 5: ...e high mechanical and corrosion resistance Pressure reducer In the back plate connection is housed the pressure reducer which is pre calibrated at the factory with an outlet pressure of 3 bar This val...

Page 6: ...t the turning of the green upper knob until the complete cleaning of the filtering cartridge is obtained Turn the filtering knob until the filtering position is reached with the discharge valve closed...

Page 7: ...1 8 Insert a curved pincer inside the discharge valve and rotate it clockwise to close the valve completely 1 9 Screw the brass nut insert the green plastic cover and put in the fork up as the initial...

Page 8: ...agraph 5 1 5 Placing the filter in phase Increase of the pressure downstream the pressure reducer in the presence of a boiler Water overheating increase of water volume Install an expansion tank The p...

Page 9: ...ents for performances safety and testing Acqua Brevetti 95 S r l operates with a Quality System certified according to Standard UNI EN ISO 9001 2000 with certificate N 50 100 7368 drafted by T V Itali...

Reviews: