DC Inverter
X-
Series for R410A Unitary Split Air Conditioner
18
3.3 Electrical Installation
3.3.1 Requirement and Notice on Electrical Installation
The electrical installation for the air conditioner should observe the following
requirements:
①.
The electrical installation must be conducted by professionals in compliance
with local laws and regulations and the instructions in this manual. Never
extend the power cord. The electric circuit must be equipped with a circuit
breaker and air switch both with sufficient capacity.
②.
The unit’s operating power must be within the nominal range stated in the
instruction manual. Use a specialized power circuit for the air conditioner. Do
not draw power from another power circuit.
③.
The air conditioner circuit should be at least 5
feet
away from any
inflammable
surface.
④.
The external power cord, the temperature controller wire and outdoor unit
must be effectively fixed.
⑤.
The external power cord, the temperature controller wire and outdoor unit
can’t directly contact any hot objects. For example: they must not contact
chimney pipes, warm gas pipes or other hot objects.
⑥.
The external power cord, and the temperature controller wire and outdoor unit
must not be squeezed. Never pull, stretch or bend the wires.
⑦.
The external power cord, the temperature controller wire and outdoor unit
must not collide with any metal beam or edge on the ceiling, or touch any
metal burrs or sharp metal edge around.
⑧.
Connect wires correspondingly by referring to the circuit diagram labeled on
the unit or electric box. Screws must be tightened up. Slipped screws must be
replaced by specialized flat-head screws.
⑨.
Please use the power cables that are delivered along with the air conditioner.
Do not change the power cables arbitrarily. Do not change the length and
terminals of the power cables. If you want to change the power cables, please
contact
$&352
’s local service center.
⑩.
Wiring terminals should be connected firmly to the terminal board. Loose
connection is forbidden.