 Component Testing Procedures 

 

Illustration 

Component 

Test 

Results 

 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
Cavity 

TCO………… ...................................... 

 
Magnetron TCO .............................................. 

 

 

Open at 203° F (95° C) Closes at 185° 
F (85° C) 
 
Open at 293° F (145° C) Closes at 275° 
F (135° C) 

 

Diode/Rectifier 

Discharge Capacitor 

 

Remove diode lead from capacitor and 
connect ohmmeter. 

 

Reverse leads for second test. 

Infinite resistance should be measured 
in one direction and 50KΩ or more in 
the opposite direction. 

 

NOTE: 

Test meter must contain a 

battery of 6 volts minimum. 

 

 

Capacitor 

Discharge Capacitor 

 

Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 

 
 

 

Also check between each terminal and 
capacitor case. 

  

Check 1.20uf value for + or 

– 3% 

 

Between Terminals: 

Meter should 

momentarily deflect towards zero then 
return to over 5 MΩ. If no deflection 
occurs, or if continuous deflection 
occurs, replace capacitor. 

 

Terminal to Case: 

Infinite resistance. 

 

 

Magnetron 

Discharge Capacitor 

 

Remove wires from magnetron and 
connect ohmmeter to terminals. Also check 
between each terminal and ground. 

2M248(J)A 

–B2 

Between Terminals: 

Less than 1 Ω. 

 

Each terminal to ground measures 
Infinite resistance. 

NOTE: 

This test is not conclusive. If 

oven does not heat and all other 
components test good replace the 
magnetron and retest. 

 

 

Stirrer Motor 

Remove all wires from terminals. 

 

Measure resistance from: 

terminal to terminal...................................... 

 

   230vac 50hz 29.1rpm

 

   

Bidirectional 

Approximately 4 

KΩ. 

 

 

 

Blower Motor 

Remove all wires from motor. 

 

Measure resistance from terminal to 
terminal… ....................................................... 

 
 

 

Approximately 50 

Ω. 

230vac 50hz 2800rpm 

 

Fuse block / Filter 
assembly  
 
20A Fuse 

Power In terminals ....................................... 
Power Out terminals .................................... 
 
Continuity Test 

230 VAC 
230 VAC 
 
Rated  20A  250vac 

 

LED Lamp 

Power across terminals 

230vac = light 
 
48 lumens 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor 
before servicing, unless testing requires power. 

 

 

Summary of Contents for RMS510TS2

Page 1: ...z 16A CEE 7 7 Schuko RMS510TSUA EMEA UK LATAM Touch 1500 W 7 3 A 230v 50hz 13A BS1363 A RMS510DSUA EMEA UK LATAM Dial 1500 W 7 3 A 230v 50hz 13A BS1363 A RMS510TSAA Australia Touch 1500 W 7 3 A 230v 50hz 10A Type 1 RMS510TSCA China Touch 1500 W 7 3 A 230v 50hz 16A China RMS510TSIA India Touch 1500 W 7 3 A 230v 50hz 16A BS546 Models RMS510D RMS510T Power Output Nominal microwave energy IEC705 1000 ...

Page 2: ... no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground 2M248 J A B2 Between Terminals Less than 1 Ω Each terminal to ground measures Infinite resistance NOTE This test is not conclusive If oven does not heat...

Page 3: ...om Terminal C to NO Secondary Terminal C to NC Monitor Terminal C to NO Primary Logic With door closed measure resistance from Terminal C to NO Secondary Terminal C to NC Monitor Terminal C to NO Primary Logic Infinite Continuity Infinite Continuity Infinite Continuity Primary Interlock Switch Wire Harness Disconnect wires to switch Continuity Service Mode To avoid risk of electrical shock persona...

Page 4: ...3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle remove test container Using the thermometer stir water for five to ten seconds and record temperature T2 6 Subtract the starting water temperature T1 from th...

Page 5: ...9 2019 ACP Inc 5 16500066 Wiring and Schematic Diagrams To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power ...

Page 6: ...f no power chosen PL10 is default 5 Press START key to begin cooking Oven begins cooking and the LED displays cooking time 6 At the end of the cooking cycle the oven beeps and LED displays End Operating Preset Program Keys From the factory this oven can of store up to 10 preprogrammed cooking sequences in memory for one key touch operation 1 Open oven door and place food in oven Close door 2 Press...

Page 7: ...d item to be cooked at once Note X2 function may be used only with Preset Program Number Keys 1 Open oven door and place food in oven Close door 2 Press X2 key LED displays doub 3 Press desired Preset Program Number Key s LED displays the cooking time for two quantities The oven will start cooking per the quantity preset cooking time 4 At the end of the cooking cycle the oven beeps and LED display...

Page 8: ...ep Sets volume to low Sets volume to medium Sets volume to high 3 Key Beep OP 30 OP 31 Prevents beep when pad is pressed Allows beep when pad is pressed 4 Active Display OP 40 OP 41 OP 42 OP 43 15 seconds after oven door is opened keyboard disabled 30 seconds after oven door is opened keyboard disabled 1 minute after oven door is opened keyboard disabled 2 minutes after oven door is opened keyboar...

Reviews: