background image

Wiring Diagram and Schematic 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

October 2012 

 

16500021

 

©2012 ACP Inc.

 

5

 

Summary of Contents for RCS511DS

Page 1: ...ury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models RCS511DS Power Source Voltage AC 230 VAC Amperage Single Unit 15 A Frequency 50 Hz Single Phase 3 wire grounded X Receptacle CEE 7 7 Schuko Plug CEE 7 7 Schuko Power Output Microwave Nominal microwave energy IEC705 1000 Watts Minimum temperature rise T 10ºF 5ºC Operating Frequency 24...

Page 2: ...ween Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground Between Terminals Less than 1 Ω Each terminal to ground measures...

Page 3: ...om Monitor Terminals 3 4 Primary Terminals 1 2 Secondary Terminals 5 6 With door closed measure resistance from Monitor Terminals 3 4 Primary Terminals 1 2 Secondary Terminals 5 6 After verifying or replacing the module re connect wires to switch and check operation of monitor circuit before operating the oven Indicates continuity Infinite Ω Infinite Ω Infinite Ω Indicates continuity Indicates con...

Page 4: ...ture should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle remove test container...

Page 5: ...m and Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power October 2012 16500021 2012 ACP Inc 5 ...

Reviews: