![ACP MXP5201 Service Manual Download Page 25](http://html.mh-extra.com/html/acp/mxp5201/mxp5201_service-manual_2840412025.webp)
23
Service Test
Radiant Heater
Screen
This screen will allow operation of the
radiant heater and show the number of
amps being drawn.
NEXT TEST:
Press this pad to go to the
next Service Mode Test
PREV TEST:
Press this pad to go to the
previous Service Mode Test
TURN ON:
This pad will toggle between
turning the heater on and off.
CANCEL:
Press this pad to return to the
Main Menu
RANGE:
Under normal operation, the amp
draw should be
10 – 16 amps.
Convection Fan – Low Speed
Screen
This screen will allow operation of the
convection fan at a low speed and show the
number of amps being drawn.
NEXT TEST:
Press this pad to go to the
next Service Mode Test
PREV TEST:
Press this pad to go to the
previous Service Mode Test
TURN ON:
This pad will toggle between
turning the convection fan on and off at a
low speed.
CANCEL:
Press this pad to return to the
Main Menu
RANGE:
Under normal operation, the amp
draw is too low to read.