background image

Component Specifications 

 

!

WARNING

 

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor  

 

before servicing, unless testing requires power. 

16500017  

July 

2010 

  

©2010 ACP, Inc. 

2

 

Illustration Component 

Testing 

 

Results 

 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
Cavity Thermal Fuse ......................................
Magnetron TCO..............................................

 
 
Open at 104° C (219° F). 
Open at 138° C (280° F) and  

closed at 82° C (180° F). 

 

Diode Assembly 

Discharge Capacitors

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance should be 
measured in one direction and 50K

 

or more in the opposite direction. 
 

NOTE:

 Analog meter must contain a 

battery of 6 volts minimum. 

MT2

MT1

GA TE

 

Triac 

Disconnect wires to triac. 
 
Measure resistance from: 
MT1 to MT2 ....................................................
MT1 to Gate....................................................
MT2 to Gate....................................................
All terminals to ground....................................

Caution - Do not operate oven with 
wire to terminal MT2 removed.

 

 
Infinite. 
Approximately 40 

 or more. 

Infinite. 
Infinite. 

 

Capacitor 

Discharge Capacitors

 

 
Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
 
Also check between each terminal and 
capacitor case. 

 
 

Between Terminals: 

Meter should 

momentarily deflect towards zero 
then return to over 5 M

. If no 

deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
 

Terminal to Case:

 Infinite 

resistance. 

 

Snubber Assembly 

Disconnect wires to snubber. 
 
Measure resistance across terminals.............

 
 
Infinite. 

 

Magnetron 

Discharge Capacitors

 

 
Remove wires from magnetron and 
connect ohmmeter to terminals. Also check 
between each terminal and ground. 

Between Terminals:

 Less than 1 

.

 

 
Each terminal to ground measures 
Infinite resistance. 

NOTE:

 This test is not conclusive. If 

oven does not heat and all other 
components test good replace the 
magnetron and retest. 

 

Blower Motor 

Remove all wires from motor. 
 
Measure resistance across coil ......................

 
 
Approximately 30 

.

 

Earth

Load

Line

 

Line Filter 

Line to Line .....................................................
Load to Load...................................................
Line to Load ....................................................
Any terminal to Earth ......................................

.8 M 

.

 

.8 M 

.

 

Continuity. 
Infinite. 

Wire Harness 

 

Test continuity of wires ................................... Continuity. 

Summary of Contents for Menumaster DEC21E2

Page 1: ... risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models MCHDC521 DEC21E2 HDC5212 CHDC5212 Power Source Voltage AC 230 VAC 230 VAC Amperage single unit 16 A 32 A Frequency 50 Hz 50 Hz Single phase 3 wire earthed X X Plug Marechal DS3 CEE 7 7 Schuko Power Output Nominal microwave energy IEC705 2100 Watt...

Page 2: ...ximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Termina...

Page 3: ...Ω Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NO Primary Terminal C to NO Secondary Terminal C to NC Monitor With door closed measure resistance from Terminal C to NO Primary Terminal C to NO Secondary Terminal C to NC Monitor Door Closed Primary Logic C NC NO C C NO Secondary Monitor Infinite Infinite Co...

Page 4: ...tage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3 Replace HV LV Board F4 Replace HV LV Board F5 Replace Touch Panel F6 Replace HV LV Board Usage Test The Usage Test is used to access Magnetron Hours Magnetron Cycles and Door Cycles Use the following procedure to access the data ...

Page 5: ...he 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechani...

Page 6: ...AG TCO BK WH LOWER ANTENNA MOTOR WH BU GY 19 230 COM HV 4 6 7 PK 11 RD 15 WH 26 BU 29 OR 7 WH 28 OVEN THERMAL LINK TOROID TOROID POWER CORD A B C D TERM BLK WH 28 BU BR BU LINE FILTER BK LINE LOAD L1 L1 L2 L2 BR BU BU BR CL BK CL GN YL WH 1 MON FUSE A B C D TERM BLK LINE FILTER LINE L1 L2 L1 LOAD L2 BLOWER MOTOR NO NC OR 9 WH 3 WH 2 WH 3 SECONDARY COM COM NO NC MONITOR BU 14 OR 8 BK 23 WH 1 UPPER ...

Page 7: ...R AUX CONTROL BOARD MONITOR SWITCH MAGNETRON 1 TOP MAGNETRON 2 BOTTOM BOT MAG TCO POWER TRANSFORMER 230 M OVEN LIGHT NOT ON ALL MODELS M INTERLOCK SWITCH SECONDARY LOWER ANTENNA MOTOR UPPER ANTENNA MOTOR UPPER ANTENNA MOTOR TOP MAG TCO 20A FUSE LINE FILTER INTERLOCK SWITCH PRIMARY OVEN THERMAL LINK POWER CORD F FA RECTIFIER FA F C C C NO SECONDARY DOOR CLOSED INTERLOCK SWITCH SCHEMATIC NC MONITOR ...