17
Touch Panel Assembly
Disconnected from Main Board
Pad Traces
1 1 to 8 to 10 0-150
Ω
2 1 to 7 to 10 0-150
Ω
3 1 to 6 to 10 0-150
Ω
4 1 to 5 to 10 0-150
Ω
5 1 to 4 to 10 0-
150Ω
6 1 to 3 to 10 0-150
Ω
7 1 to 8 to 9 0-150
Ω
8 1 to 7 to 9 0-150
Ω
9 1 to 6 to 9 0-150
Ω
0 1 to 5 to 9 0-150
Ω
Start 1 to 4 to 9 0-150
Ω
Stop 1 to 4 to 8
0-150
Ω
SERVICE MODE
TO ACCESS THE SERVICE MODE:
PRESS AND HOLD THE “7” PAD UNTIL THE PIN PROMPT IS DISPLAYED
AT THE PIN PROMPT, ENTER 1,3,5,7 then 9 THEN SELECT FROM THE
FOLLOWING:
o
1
– USAGE
This shows Door Cycles, Tube Cycles, and Tube Hours.
o
2 - ERROR HISTORY
This shows any Error Codes that have occurred
o
3 - PIN CODE
This reveals the 4 digit PIN code required for programming (if enabled)
o
4 - VOLTAGE SWITCHING (not available on 120vac units)
Allows selection of Forced 208, Sensing (Auto Sense), or Forced 230
o
5 - EXPORT TO USB
This option requires a USB be inserted. Files that contain USAGE,
OPTIONS & ENGINEERING SETTINGS, MENU PROGRAMMING, and
ERROR CODES will be downloaded.
NOTE: Pressing the
grey “stop” pad will navigate backwards.
Summary of Contents for MDC182SA
Page 9: ...9 OVEN CONSTRUCTION BLOWER CAPACITOR DIODE INTERLOCK ...
Page 10: ...10 DOOR ...
Page 11: ...11 CONTROL BOARD MAGNETRONS DUCTS FUSE ...
Page 12: ...12 TRAY CAVITY ANTENNAS ...
Page 13: ...13 WRAPPER ACCESS PANEL LAMP ...
Page 19: ...19 HDC12A2 P2007001M MDC12A2 P2007002M WIRING AND SCHEMATIC DIAGRAMS ...
Page 21: ...21 MDC182SA P2007025M MDC212SA P2007031M MDC212B P2007032 ...
Page 22: ...22 MMDC182K P2007007M ...
Page 23: ...23 MCHDC21T P2007030M ...