5
Grounding Instructions
WARNING
To avoid risk of electrical shock or death, this oven
must be grounded.
WARNING
To avoid risk of electrical shock or death, do not alter
the plug.
This oven MUST be grounded. In the event of an
electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the
electric current. This oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
Consult a qualified electrician or servicer if grounding
instructions are not completely understood, or if doubt
exists as to whether the oven is properly grounded.
Do not use an extension cord. If the product power
cord is too short, have a qualified electrician install a
three-slot receptacle. This oven should be plugged into
a separate circuit with the electrical rating as shown in
the appropriate drawing. This oven requires a 208-230
supply voltage. When a microwave oven is on a circuit
with other equipment, an increase in cooking times may
be required and fuses can be blown.
Earthing Instructions
Oven MUST be earthed.
Earthing reduces risk of
electric shock by providing an escape wire for the
electric current, if an electrical short occurs. This oven is
equipped with a cord having a earth wire with a earthing
plug. The plug must be plugged into an outlet that is
properly installed and earthed.
Consult a qualified electrician or servicer if earthing
instructions are not completely understood, or if doubt
exists as to whether the oven is properly earthed.
Do not use an extension cord.
If the product power cord is too short, have a qualified
electrician install a three-slot receptacle. This oven
should be plugged into a separate circuit with the
electrical rating as provided in product specifications
(available on Amana’s wavelink website). When a
microwave oven is on a circuit with other equipment, an
increase in cooking times may be required and fuses
can be blown.
External Equipotential Earthing Terminal
(export only)
Equipment has secondary earthing terminal. Terminal
provides external earthing connection used in addition
to earthing prong on plug. Located on outside of oven
back, terminal is marked with symbol shown below.
WARNING
WARNING
To avoid risk of electrical shock or death, this oven must
be grounded.
To avoid risk of electrical shock or death, do not alter
the plug.