Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

January 2009 

 

16500008 

©2009 ACP Inc. 

Replaces 16027357

 

 

3

 

Illustration 

Component 

Test 

Results 

208

COM

230

120

 

Auto Transformer 

230

208

120

0

 

Discharge Capacitors 

Remove all wires from terminals. 
 
Measure resistance from: 
230 to 0 ...........................................................
208 to 0 ...........................................................
120 to 0 ...........................................................

 
 
 
 
42.4 

38.6 

21.5 

 

 

1

3

2

4

7

6

5

8

 

Terminal 1 

 

  Common 

Terminal 2 

 

 208 V 

Terminal 3 

  

230 V 

Transformer 
 

# 4

# 1

# 3

# 2
# 5
# 6
# 7
# 8

1.0  F

-300 MA

-300 MA

1.0  F

 

Discharge Capacitors 

Remove all wires from terminals. 
Measure resistance from: 
Terminal 1 to 2 ................................................
Terminal 1 to 3 ................................................
Terminal 5 to 6 ................................................
Terminal 7 to 8 ................................................
Terminal 4 to Ground screw on transformer ....
Terminal 4 to any other terminal ......................

 

Gray

Violet

Red

1

3

2

 

 

 
 
Less than 1 

 

Less than 1 

Less than 1 

Less than 1 

30 

Infinite resistance. If not, replace 
transformer. 

Primary /
    Logic

Secondary

Mo nitor

 

Interlock switch 
assembly 

Disconnect wires to switch. 
 
With door open measure resistance from: 
Terminal C to NC      Monitor ..........................
Terminal C to NO      Primary / Logic ..............
Terminal C to NO      Secondary .....................
 
With door closed measure resistance from: 
Terminal C to NC      Monitor ..........................
Terminal C to NO      Primary / Logic ..............
Terminal C to NO      Secondary .....................
 

Door Closed

 

Primary / Logic C

NC

NO

C

C

NO

Secondary

Monitor

 

 

 
 
 
Continuity. 
Infinite. 
Infinite. 
 
 
Infinite. 
Continuity. 
Continuity. 

 

Touch Panel 
Assembly 

Continuity is indicated as 100 

 and below. 

 

Pin 1:

 Ground. 

 

 

Pad

 











Start 
Stop/Reset 
Power Level 
X 2 
Time Entry 

Pins 

8 & 10 
7 & 10 
6 & 10 
5 & 10 
4 & 10 
3 & 10 
8 & 9 
7 & 9 
6 & 9 
5 & 9 
4 & 9 
4 & 8 
5 & 8 
6 & 8 
7 & 8 

Measurement 

Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity

 

Wire Harness 

 

Test continuity of wires.................................... Continuity. 

 

Summary of Contents for HDC182

Page 1: ...the risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models HDC182 HDC18SD2 CRC18T2OG2 HDC212 HDC21RB2 HDC21RT2 CRC21T2RL2 Power Source Voltage AC 230 208 VAC 230 208 VAC Amperage Single Unit 20 A 20 A Frequency 60 Hz 60 Hz Single Phase 3 wire grounded X X Receptacle 6 20R 6 20R Plug 6 20P 6 20P Power ...

Page 2: ...e to terminal MT2 removed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous def...

Page 3: ...ed 1 3 2 Less than 1 Ω Less than 1 Ω Less than 1 Ω Less than 1 Ω 30 Ω Infinite resistance If not replace transformer Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door closed measure resistance from Terminal C to NC Monitor Terminal C...

Page 4: ...tically switches for 208 or 230 VAC operation Control board Terminals F H Line voltage All Conditions 0 VAC Idle and Standby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3...

Page 5: ... container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with...

Page 6: ... To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16500008 January 2009 Replaces 16027357 2009 ACP Inc 6 12844901 DANGER HIGH VOLTAGE ...

Page 7: ... To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power January 2009 16500008 2009 ACP Inc Replaces 16027357 7 12844901 DANGER HIGH VOLTAGE ...

Reviews: