Power line carrier principle
Power line carrier transmission
The principle of “PLC” transmissions is to stack an enco-
ded signal with a higher frequency and weaker amplitude
on the signal present between the live and neutral wires
(230 V, 50 Hz).
The programmer can
be used in blue tariff
installations with an
area less than 180 m
2
.
The DELTA DORE X2D
protocol conforms to the
NF-EN50065-1 standard which allows several PLC
systems that comply with the standard to coexist in
one installation.
Advantages:
- No damage to the existing installation – Upgradeability
of the system
- Diversity of receivers
- No filter necessary at the head of electric installation.
50 Hz
Carrier
frequency
Mains network
230V
Transmitter
Receiver
- Standard UTE NF C15-100 and good practice must be complied
with.
- Connected or nearby equipment must not generate excessive
interference (directive 2004/108/CE).