![Acova ATOLL SPA SL-080-050 Instructions For Use Manual Download Page 22](http://html.mh-extra.com/html/acova/atoll-spa-sl-080-050/atoll-spa-sl-080-050_instructions-for-use-manual_2840392022.webp)
42
43
EN
EN
40017784
07/2018
C.
To start the appliance, follow the same procedure as for an electric towel-dryer.
If the central heating system is equipped with a circulation pump which is inde-
pendent of the boiler,
it must in all circumstances be turned off
(risk of siphoning the
heating unit in the event that connections are not perfectly watertight).
IMPORTANT
The appliance should only be turned on when properly filled with water
(failure to comply may invalidate the guarantee).
IMPORTANT
This radiator is equipped with a resistance which has an integrated
power shut-off and fuse. Using the radiator without water will permanently damage
the fuse as well as the resistance. In this case it must be changed though "
not
under the manufacturer’s guarantee
". Using the radiator only partially filled with
water causes the heating function to shut off automatically. Alternate function will
continue as long as the main heating section is not properly filled.
If you notice that the electrical part of your towel dryer is activated, but that it
fails to heat up inspite of thermostat demand or positive working operation, carry out
the following operations:
1) Ascertain that your radiator is full of water (see
paragraph B
).
2) Press button
❶
(see
chapter 4.1
) to stop current supply and stop the elec-
trical function for 30 to 60 minutes. This operation is necessary to cut off the thermal
safety device.
3) Turn the appliance on by pressing the button
❶
. The thermostat will dis-
play an error to show water is low (red
❷
indicator flashing and orange
❹
indicator
flashing). Press the button
❸
for 5 seconds to reset the safety device. The appliance
will restart normally.
4. Using your thermostat
4.1 Overview
❶
❺
❷
❻
❼
❸
❹
❶
Heating stop/start button
❷
On indicator
❸
Two-hour booster button
TIMERPROG
❹
Functioning indicator
❺
Adjustment dial
❻
Knob for temperature setting
❼
Setting marker
Your appliance can be configured in several different ways (see tables on the
following pages for details of the LED displays):
-
manually
, with the settings buttons (see
chapter 4.2
);
- with a
pilot wire controller
(see
chapter 4.5
);
- with the Acova Control smartphone
application
(see
chapter 4.7
).
You can define a
weekly user programme (PU)
with the
Acova Control
smartphone app. This programme lets you choose the heating temperature for your
appliance for every hour on each day.
WARNING!
Do not pair your Timer unit directly using your smartphone's Bluetooth
parameter options if it invites you to do so.
Pairing must
only
be done from the app, so that it works correctly.
Summary of Contents for ATOLL SPA SL-080-050
Page 33: ...www acova fr ...