Acoustic AG120S User Manual Download Page 2

w w w . a c o u s t i c a m p l i f i c a t i o n . c o m

ExposurE to high noisE lEvEls may causE pErmanEnt hEaring loss. individuals vary considErably to  
noisE-inducEd hEaring loss but nEarly EvEryonE will losE somE hEaring if ExposEd to sufficiEntly intEnsE 
noisE ovEr timE.

the u.s. government’s occupational safety and health administration (osha) has specified the following permissible noise level exposures:

2

IMpoRtANt SAfEty INStRUctIoNS

DURATION PER DAY (HOURS)  8 

1/2hr. or less 

 

SOUND LEVEL (dB) 

90 

93  95 

97 

100  103 

110

This symbol is intended to alert the user to the presence of  
non-insulated “dangerous voltage” within the product’s enclosure. 

This symbol is intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the literature 
accompanying the unit.

Apparatus shall not be exposed to dripping or splashing. Objects 
filled with liquids, such as vases, shall not be placed on  
the apparatus.

  1.   Read all safety and operating instructions before using this product.

  2.   All safety and operating instructions should be kept for future reference.

  3.   Read and understand all warnings listed on the operating instructions.

  4.   Follow all operating instructions to operate this product.

  5.    This product should not be used near water, i.e., bathtub, sink, swimming 

pool, wet basement, etc.

  6.   Only use dry cloth to clean this product.

  7.   Do not block any ventilation openings, it should not be placed flat against a 

wall or placed in a 

built-in enclosure that will impede the flow of cooling air.

  8.   Do not install this product near any heat sources such as radiators, heat 

registers, stoves or other apparatus (including amplifiers) that produce heat.

  9.   Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. A 

grounding-type plug has two blades and a third grounding prong. The wide 

blade or the third prong are provided for your safety. If the  

provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

 10.   Protect the power cord from being walked on or pinched, particularly at 

plugs, convenience receptacles, and the point where  

they exit from the apparatus. Do not break the ground pin of the power 

supply cord.

 11.  Only use attachments specified by the manufacturer.

 12.   Use only with the cart, stand, tripod, bracket, or table specified by the 

manufacturer or sold with the apparatus. When a cart is used, exercise 

caution 

when moving.

 13.   Unplug this apparatus during lightning storms or when unused for a long 

period of time.

 14.   Care should be taken so that objects do not fall and liquids are not spilled 

into the unit through the ventilation ports or any other openings.

 15.   Refer all servicing to qualified service personnel. Servicing is required when 

the apparatus has been damaged in any way. 

 16.   WARNING: To reduce the risk of fire or electric shock, do not expose this 

apparatus to rain or moisture.

 17.   When a mains plug or an appliance coupler is used as the disconnect device, 

the disconnect device shall remain readily operable.

 18.   An apparatus with CLASS 1 construction shall be connected to a MAINS 

socket outlet with a protective grounding connection.

FCC Statement

This device complies with Part 15 of the FCC rules. Operation is subject to the  

following two conditions.

1.  

this device may not cause harmful interference and

2.  

this device must accept any interference received including interference that 

may cause undesired operation..

All trademarks and registered trademarks mentioned herein are recognized as 

the property of their respective holders.

California Prop 65 Warning

This product may contain a chemical[s] known to the state of California to cause 

cancer, birth defects, or other reproductive harm.

0906-9008

According to OSHA, any exposure in the above permissible limits 
could result in some hearing loss. Hearing protection must be 
worn when operating this amplification system in order to prevent 
permanent hearing loss.

Summary of Contents for AG120S

Page 1: ...AG120S USER S MANUAL 1 2 0 W A T T s t e r e o a c o u s t i c p e r f o r m a n c e s y s t e m w w w a c o u s t i c a m p l i f i c a t i o n c o m the pro s tone since 1967 ...

Page 2: ...lade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Do not break the ground pin of the power supply cord 11 Only use attachments spec...

Page 3: ...ginal owner from the date of purchase Retailer and manufacturer shall not be liable for damages based upon inconvenience loss of use of product loss of time interrupted operation or commercial loss or any other incidental or consequential damages including but not limited to lost profits downtime goodwill damage to or replacement of equipment and property and any costs of recovering reprogramming ...

Page 4: ...usicians including some of music s premier rock jazz and funk players have chosen Acoustic as their amplifier of choice The Acoustic design philosophy is simplicity allowing you to dial up great sound in an instant The AG120S continues the great Acoustic tradition of simply great sound so turn it up and discover what players have known for decades Acoustic the Pro s Tone since 1967 welcome and Con...

Page 5: ...damage To avoid damage turn off the AG120S power switch and all related devices prior to connecting or disconnecting cables HANDLING AND TRANSPORT Never apply excessive force to any parts Unplug cables by gripping plugs firmly Do not pull on cables Physical shocks caused by dropping or bumping can result in serious damage CLEANING Clean with a dry soft cloth A slightly damp cloth may be used to re...

Page 6: ...an sweep between 500Hz and 1 2kHz Moving cutting or boosting these mid frequencies will give you maximum control over the body of your tone This control can also be useful in eliminating acoustic feedback It also allows you to control the definition and voice of your acoustic instrument 5 High frequency control set to boost 15 dB or cut 15 dB frequencies at 10 kHz Increasing this will enhance the ...

Page 7: ...owered monitor speaker or additional amplifier 2 The Stereo Line Out section is extremely versatile and includes a balanced XLR output jack and an unbalanced 1 4 jack for each of the internal power amplifiers both of which may be used simultaneously The Line Out Level control is strictly for level adjustment of the Line Out signal and will not affect the stage volume of the amplifier Conversely th...

Page 8: ...atts 15 heavy duty speaker 4 Band EQ with notch filter Passive and active inputs B100 Ideal portable rehearsal amp 20 Watts 12 custom speaker 4 Band EQ Dual instrument inputs B20 The ultimate in tone power and protection 8x10 800 Watt power handling 4 Ohms 1 4 Speakon inputs Heavy duty casters B810 Massive output for stadium sound 600 Watts 6 Band EQ and notch filter Passive and active inputs Dire...

Reviews: