-SO Sensor Operation
Range Adjustment
1. Make sure power supply is disconnected from
sensor and make short circuit on red wires.
See DETAIL A.
5. Hold hand at desired sensing distance until red light
stops flashing and solenoid activates.
See DETAIL C.
2. Connect power supply to sensor. Red light should
be flashing.
3. Move hand in front of sensor to distance of 2” to 4”
within 5 seconds and wait until red light flashes
quickly.
4. Move hand to desired sensing distance.
See DETAIL B.
DETAIL A
DETAIL B
DETAIL C
Transformer must
be plugged into a
GFI protected
circuit. Fixture must
be earth grounded
per N.E.C. or
applicable codes.
Jumper
By Others
-SO Sensor Operation
Model 3753-1-HLH-SO Shown
SENSOR OPERATION & CONNECTIONS
Page 12 of 27
Part #: 6215-371-000
®
MERIDIAN 3753-HLH
Revised: 03/05/19
-SO SENSOR
-PPZ PUSHBUTTON
RED
BLUE
RED
BLUE
TRANSFORMER
SOLENOID VALVE