Heat pumps AIR / WATER

 

 

Operation manual

 

 

44

 

 

Model(s) 

PRO-N

 

Heat pump air / water: (yes/no) 

yes 

Heat pump solution-water: (yes/no) 

no 

Heat pump water-water (yes/no) 

no 

Low-temperature heat pump (yes/no) 

no 

Equipped with a supplementary heater (yes/no) 

no 

Combined heater with heat pump: (yes/no) 

no 

Application: (low temperature/medium temperature)

 

medium-temperature 

Climatic conditions: (colder/average/warmer)

 

Average 

Item 

Label 

Value 

Unit 

 

Item 

Label 

Value 

Unit 

Rated heat output (

1

)

 

Prated 

kW 

 

Seasonal energy 
efficiency of heating 

S

 

144

 

Declared heating output for partial load at indoor temperature 
20 °C and outdoor temperature Tj 

 

Declared heat factor or coefficient of primary energy ratio 
for partial load at indoor temperature 20 °C and outdoor 
temperature Tj 

Tj = -7°C 

Pdh 

4.1 

kW 

 

Tj = -7°C 

COPd 

2.4 

Tj = +2°C 

Pdh 

2.5 

kW 

 

Tj = +2°C 

COPd 

3.7 

Tj = +7°C

 

Pdh 

1.6 

kW 

 

Tj = +7°C 

COPd 

4.4 

Tj = +12°C

 

Pdh 

1.8 

kW 

 

Tj = +12°C 

COPd 

5.4 

 

Tj = bivalent temperature 

Pdh 

4.6 

kW 

 

Tj = bivalent temperature  COPd 

2.1 

Tj = operation limit temperature 

Pdh 

4.6 

kW 

 

Tj = operation limit 
temperature 

COPd 

2.1 

For air-to-water heat pumps Tj 
= -15°C (if TOL< -20°C) 

Pdh 

kW 

  For air-to-water heat 

pumps Tj = +15°C (if 
TOL < -20°C) 

COPd 

Bivalent temperature 

T

biv

 

-10 

°C 

 

For air-to-water heat 
pumps: Operation limit 
temperature 

TOL 

-10 

°C 

Cycling interval capacity for 
heating 

Pcych 

kW 

 

Cycling interval capacity 
for heating 

COPcyc 

Energy loss coefficient (2) 

Cdh 

0.9 

 

Domestic hot water 
operating limit 
temperature 

WTOL 

70 

°C 

Power consumption in modes other than active mode 

 

Supplementary heater 

Off mode 

P

OFF

 

0.016 

kW 

 

Rated heat output (

1

)

 

Psup 

kW 

Thermostat-off mode 

P

TO

 

0.016 

kW 

 

Type of energy input 

Electrical 

Standby mode 

P

SB

 

0.016 

kW 

 

Compressor cabinet heating 
mode 

P

CK

 

kW 

 

Additional items 
Performance regulation 

Variable 

 

For air-to-water heat 
pumps: Rated air flow 
rate, outdoors 

1600 

m

3

/h

 

Sound power level, 
indoors/outdoors 

L

WA

 

-/48,4 

dB 

 

For water-/brine-to-water 
heat pumps: Nominal 
brine or water flow rate 

m

3

/h

 

Emissions of nitrogen oxides 

NO

x

 

mg/kWh   

For heat pump combination heater: 
Declared load profile 

 

Water heating energy 
efficiency 

wh

 

 

Electricity consumption 

Q

elec

 

kWh 

 

Daily fuel consumption 

Q

fuel

 

 

kWh 

Contact  information 

Acond a.s., Štěrboholská 1434/102a, 102 00 Prague 10 – Hostivař, Czech Republic 

 

 

 

Summary of Contents for PRO-N

Page 1: ...witches the heat pump off To set the room temperature Press the rotary button The desired indoor temperature flashes on the display Turn the button to the right to increase the desired room temperatur...

Page 2: ...mperature 15 3 1 6 How to Determine Outdoor Temperature 15 3 1 7 How to Detect and Change service water Temperature 15 3 1 8 How to set the end of heating temperature 15 3 1 9 Display Fault Confirmati...

Page 3: ...Heat pumps AIR WATER Operation manual 3 7 TECHNICAL INFORMATION IN ACCORDANCE WITH COMMISSION REGULATION EU NO 813 2013 42 8 LINKS 45...

Page 4: ...ing installation operation and maintenance then the obligations of ACOND a s stemming from the terms of the warranty shall cease to apply ACOND a s hereby reserves the right to make changes to any par...

Page 5: ...locally applicable occupational safety and other safety regulations This applies in particular to the use of personal protective clothing 2 1 1 Personal protective equipment Every person performing m...

Page 6: ...can be used for degreasing Due to the risk of damage to the heat pump casing do not use any spray types in its vicinity This applies in particular for Solvents Chlorine cleaning products Paints Adhesi...

Page 7: ...mate range of 5 C below the surrounding temperature and therefore the surrounding area may be icy and slippery Therefore install the heat pump in a manner that does not allow the out flowing air to in...

Page 8: ...2 3 1 Water quality and volume All water including domestic hot water must meet the parameters for drinking water according to SN 252 2004 Coll however in addition the maximum total hardness must be l...

Page 9: ...ed without a fully functioning safety valve The maximum possible operating pressure of the vessel is 0 6 MPa Occasional leakage of water from the safety valve during hot water heating is a normal phen...

Page 10: ...mensions HxWxD mm 730x1127x498 1070X1426x557 Pump weight kg 115 195 Coolant R290 R290 Coolant weight kg 1 35 2 75 Maximum allowable pressure high pressure side bar 26 26 Maximum allowable pressure low...

Page 11: ...23 COP A 7 W34 1 3 14 3 24 Heating capacity A12 W34 8 kW 1 76 3 88 COP A12 W34 8 1 5 36 5 92 Heating capacity A7 W36 kW 1 60 3 52 COP A7 W36 1 4 41 4 97 Heating capacity A2 W42 kW 2 48 5 53 COP A2 W4...

Page 12: ...lower anitfreeze at least 10 C The control maintains the set temperature in the room with a tolerance of 0 5 C The regulation will stabilize after a significant intervention within 24 hours for underf...

Page 13: ...defrosting the air heat exchanger is activated when the ACOND heat pump is running The defrost sequence starts when the evaporator temperature of the outdoor unit falls below the set value The four wa...

Page 14: ...ipped with service water heating and the service water temperature drops below the set value an accumulation vessel enabling service water preheating and the variant of preheating in summer is selecte...

Page 15: ...her heating costs 3 1 2 Meaning of individual symbols of the RCM2 1 control unit panel RCM2 1 Symbol Description Automatic mode Heat pump mode Bivalent heater mode 4 Cooling mode if installed If the r...

Page 16: ...us Circulation pump Outdoor unit shutdown domestic hot water Bivalent heater on Entering parameters service water temperature regulation type operation mode Manual regime Circulating pump plate heat e...

Page 17: ...ic view turn the button to the right A value is displayed for 5 seconds indicating the outside temperature and the thermometer symbol flashing After 5 seconds the display returns to the basic display...

Page 18: ...rs alarms of the system Instead of room temperature the two digit number indicating the fault index flashes The fault must be confirmed by a short press of the rotary button Notes For more information...

Page 19: ...nection of the heat pump to the Internet will be made by a service technician during the installation of the heat pump or later via the Acond service telephone line 420 601 373 073 Users access a web...

Page 20: ...n the lower right corner and the login table page appears see Figure 2 Type your login name in the Username field Type your password in the Password field Figure 1 Website of Acond a s with login to t...

Page 21: ...see Figure 3 to you have access the list opens by clicking the arrow in the right edge of the strip with the heat pump name Select the appropriate heat pump and click Select or press Enter The heat p...

Page 22: ...e name and password and displaying the login page on the TecoRoute server see Figure 2 TecoRoute Login Page it is possible to check the box Create a permanent login link to facilitate the next login T...

Page 23: ...heat pump parameters 1 The main page Figure 6 is displayed after logging into the system and at any time after clicking on the 1st menu line 2 Schedules Figure 11 allow you to set the value of the aut...

Page 24: ...tatus pictogra m status description Inactive Active Heat pump compressor Inactive Active Heat pump fan Inactive Active Circulating pump of heating pump Inactive Active Heat pump defrosting Winter and...

Page 25: ...e active The sun symbol indicates the summer when the heat pump only heats hot water hydrobox or maintains 45 C in the accumulation tank for service water preheating the option is located in the middl...

Page 26: ...rmed by pressing the ENTER key or by clicking the arrow in the right part of the white input field Acond Therm control normally maintains the set temperature in the room with a tolerance of 0 5 C This...

Page 27: ...other superior regulation If this is not respected we recommend using the Equitherm or Standard control 3 2 6 2 Equipment EQUIV BUTTON The temperature of the water in the heating system is determined...

Page 28: ...ter temperature in the plate exchanger for the possibility of entering the desired water temperature for cooling 3 2 7 5 Off OFF button The whole system shuts down including circulators Sometimes due...

Page 29: ...temperature accumulation container is set to 45 C Heating of the pool occurs only when the living rooms are flooded 3 2 10 Fault display In the event of a malfunction a red bar appears on the dark blu...

Page 30: ...water For each day it is possible to enter 2 time periods in which the room temperature domestic hot water temperature at ST will be controlled to the value entered in this table At the top of the tab...

Page 31: ...e 12 to enter 2 time periods in which service water heating will be enabled At the top of the table there is a choice whether the heat pump should follow the displayed schedule If the check box remain...

Page 32: ...holiday even if the heating schedule is not allowed Attention if the heating times are set so that the heating does not occur at all or only for a short period of time on time off time and the service...

Page 33: ...rol the HDO signal Bulk Remote Control switching the inexpensive electricity tariff If you check the box HDO turns off service water heating service water will not be heated at the time of the more ex...

Page 34: ...ate the temperature of the domestic hot water corresponding to these faults points The large red number in the right part of the graph corresponds to the temperature of the domestic hot water calculat...

Page 35: ...COND GENIUS heat pump information about the current system used earth or air is displayed in the top row next to the information about the installation location and pump type 4 Alarms faults and troub...

Page 36: ...aulty cable probe resistance exceeds limit values Call Service P08 SOLAR SENSOR FAULT Probe missing faulty faulty cable probe resistance exceeds limit values Call Service P09 IT S AN INTERNAL MALFUNCT...

Page 37: ...COMPRESSOR RUNNING PHASE SEQUENCE Compressor not running electrical fault balancing problems of the power grid undervoltage at some stage Check that the compressor is rotating If not call service A04...

Page 38: ...self resolve W02 LOW TEMPERATURE IN ACCU On arrival when using another heat source e g boiler at higher outdoor temperature Warning only starts the heat pump disappears on its own W03 LOW TEMPERATURE...

Page 39: ...2 Problem with compressor driver Call Service 5 Regular checks 5 1 Inspection of intake and exhaust grilles and openings Check the front grille of the fan and evaporator at regular intervals for conta...

Page 40: ...ating system e g very hard water with too much mineral content If you are not sure refer to the installation technician see chap 8 Links Do not add any additives to the water in the heating systems In...

Page 41: ...o measure the air pressure in the expansion tank air bag if the air pressure does not match the data on the expansion tank label refill the bag with air close drain valve 2 screw valve cover open ball...

Page 42: ...nd remove the filter cover keep a cloth at hand less water will leak out remove filter rinse the filter remount the filter check for damage to the sealing ring on the filter cover screw the cover back...

Page 43: ...outlet may not be fitted drain the water pressure with a hot water tap close the tap unscrew the anode the location is marked with the inscription in case of more than 50 decrease of magnesium anode...

Page 44: ...gerant circuit see chapter 8 Links 7 Technical information in accordance with Commission Regulation EU No 813 2013 1 For heaters for heating interior spaces with a heat pump and combined heaters with...

Page 45: ...limit temperature COPd 2 1 For air to water heat pumps Tj 15 C if TOL 20 C Pdh kW For air to water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 10 C For air to water heat pumps Opera...

Page 46: ...on limit temperature COPd 2 1 For air to water heat pumps Tj 15 C if TOL 20 C Pdh kW For air to water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 10 C For air to water heat pumps Ope...

Page 47: ...IR WATER Operation manual 45 8 Links In case of problems with internet connection please contact service visit the website of ACOND a s https tepelna cerpadla acond cz kontakt and click on the remote...

Reviews: