User's Manual | ACOM 2020S | 1.8-54 MHz Linear Power Amplifier
June 2022
S e c t i o n INSTALLATION | Page 27 of 76
e)
RCU's
Wi-Fi
device interface
Figure 2-6 | RCU model R05 rear panel
, Pos. 6.
This interface may remain unused until you decide to control the amplifier remotely via your local Wi-Fi
network or via Internet.
You may select either Ethernet (cable connection) or Wi-Fi (wireless connection) interface to connect the
amplifier to your local network or to Internet (see Section
6.1 Remote Control via Ethernet Interface
).
Automated software update process enables amplifier firmware download over Internet (see Section
).
f)
RCU's
USB
interface connector
Figure 2-6 | RCU model R05 rear panel
, Pos. 7 and
Table 2-6 | Signals and pin out of the RCU's USB
This connector (USB type A, female) may remain unused until you decide to update firmware of your
amplifier or to save Log Files to USB flash memory stick.
Please, see Sections
Table 2-6 | Signals and pin out of the RCU's USB type A connector
USB
interface
Pin Nr.
Pin name
Description
Colors
USB A
connector,
4-pin, female
(Rear panel view)
1
V
BUS
+5 V
Red or
Orange
2
D-
Data-
White or Gold
3
D+
Data+
Green
4
GND
Ground
Black or
Blue
Table 2-6 | Signals and pin out of the RCU's USB type A connector