Tel. +49 (0) 36965 819–0
Fax +49 (0) 36965 819–361
2
Service-Line
The LED modules with their laterally preshaped connectors
have to be fixed at the grating with the fixing pins included in
scope of supply.
Fig. 4
❸
❸
Servicing and maintenance
The LED modules have to be cleaned depending on frequency of
showering. To do this, clean the contacts with warm water and a
cloth and free them from soap residues. The LED modules need not
be removed from the grating; cleaning of contacts is sufficient for
the functioning.
The product is maintenance-free; therefore, never disassemble. Re-
pair works must always be carried out by an authorised service cen-
ter or a specialist as otherwise you risk destruction of the product.
Moreover, the approval (CE) as well as warranty claims expire.
P rior to cleaning, unplug the mains plug.
Technical data
LED module:
4x LED; colour: red / green / blue
Accumulator: U=3.6V
C=2700mAh
Wall power supply:
Primary: 230V (100-240) 50/60Hz, 180mA
Secondary: 9VDC , 800mA
Protection class: II
Charger:
U=9V DC
Imax=600mA
Initial Installation of LED modules in the
stainless steel design grating
Except from the «Tile» design, the LED modules can be inserted into
all stainless steel design gratings.
To do this, the plastic fixing pins in the grating must be remo-
ved. It is recommended to slightly compress them with the aid
of pliers and to push them outside.
Fig. 2
❶
❶
Then, the LED modules must be inserted into the design gra-
ting with the chamfered side pointing upwards. Please pay at-
tention that LED lamps always point to grating centre.
Fig. 3
❷
❷