ACO INSPIRO+VIDEO Manual Download Page 2

DISPOSAL OF WASTE ELECTRICAL EQUIPMENT 

Do not dispose of waste electrical equipment with other (household / municipal) waste types. Dispose of it separately as permitted by 
law. Consult the authority of jurisdiction or licensed waste recycling service providers. – Directive 2002/96/EC of 27/01/2003 

 

 

MOUNTING THE PANEL 

Mount the panel on the wall in a way that will minimise the effects of adverse atmospheric conditions. 
Typically, the camera should be positioned approx. 1.60 m above the ground. Ideally, you should test 
the  mounting  position  empirically. Avoid  places  where  the  camera  lens  may  be  exposed  to  direct, 
perpendicular light rays (sunlight, street lamps, etc.).

 

Install the flush mounting box using wall plugs and plaster in the appropriate wall slot so that the front 
edge is in line with the wall’s surface. 

CAUTION!

 To ensure proper operation and safety of use, provide the door phone panel (set in its metal 

frame)  with  protective  earth  bonding  by  connecting  the  earthing  terminal  on  the  housing  with  the 
appropriate earthing system (PE).

 

Connect  the panel to the entrance door electric strike and its power with a 1 mm

2

  core cable  (e.g. 

LY1.0). The cable should be no longer than 7 m for the electric strike connection and no longer than 
15 m for the power circuit connection! An insufficient power supply rating, insufficient sizes of wiring 
cores  and excessive  length of  interconnecting  wiring  (resulting  in  voltage  drops)  may  interfere  with 
proper operation (including the “humming” noise in the audio line or inadvertent triggering of the reset 
system,  especially when releasing the electric strike). The 15V DC voltage from the power adapter 
should be connected to the combiner’s terminals using a 2 x 1 mm

2

 wire.

 

If a polarity-insensitive electric strike is installed,  connect the wiring to the ELOCK terminals in any 
order. If a fail-safe (NO) electric strike is installed, connect jumper Z13 (below the resistor on the left-
hand side of the PCB)! For a fail-safe (NO) electric strike, the “ELOCK” output is live depending on the 
power adapter type; use a compatible fail-safe (NO) electric strike. An optional MOD-DC-12V module 
may be used to feed 12V DC to a fail-safe (NO) electric strike when the door phone is fed by an 15 
VDC power supply. The additional relay OUTPUT terminal (Master only) can be wired to control an 
additional entrance gate (by factory default) with a code keypad (with “the double Key button press”) 
and button F2 of the uniphone. The live voltage time and functions of the OUTPUT terminal can be 
configured using the additional I/O module, port 2 of the Program (as in the CND-I/O module). 

All wiring connections must be soldered. 

Connect the following wires to the panel: 

 

2 x 1 mm

2

 cable to power the panel (connected to the combiner),

 

 

2 x 1 mm

2

 cable: electric strike control;

 

 

1 cable wire with yellow-and-green insulation – to connect the ground of the housing. 

 

system bus (UTP cat. 5 cable, T568B standard): 1x UTP cat. 5 cable for the “Master” panel, 
2x UTP cat. 5 cable for “Slave” panel 

 

 

UNIPHONE INSTALLATION & WIRING 

Install the uniphones as specified in their original manuals. Connect the cables making sure that the 
address  in  the  monitor’s  decoder  is  set  properly  and  that  all  of  the  RJ45  connections are  clamped 
properly (T568B standard), that there are no short circuits between the cable conductors, and that the 
conductors have ducting.  If even a single RJ45 connector is clamped incorrectly or there is a short 
circuit between the wires, the monitor, splitter, or the panel itself may sustain damage.

 

 

 

VOLUME SETTING 

Set the volume as follows once the uniphone is connected properly:

 

- the “

MIC

” potentiometer is used for adjusting the sensitivity of the panel microphone

 

- the “

SPK

” potentiometer sets the speaker volume

 

- the

 

SOUNDS

” potentiometer sets the panel sound output volume

 

Having set the values, operate the “

BALANCE

” potentiometer to find the points of excitation of the 

speaker (indicated by squeaking sounds); next, adjust the potmeter halfway between these points. 

 

ELECTRICAL PARAMETERS OF THE PANEL 

 

Power supply: 13.5-15V DC (a 15V DC ACO unit is recommended) 

 

Standby mode min. power consumption: ~1.6 W 

 

Power load: max. 535 mA (not counting the electric strike) 

 

Permitted load of the electric strike output: 1 A (approx. 0.5 A for the fail-safe electric strike) 

 

Max. line length: 70 m – from the last power unit, 300 m total if extra power units are used. 

 

Installation type: digital PV system (cat. 5e or 6 cable) 

 

Compatible with the P digital system 