ACO ECOJET Installation Manual Download Page 5

ECOJET GREASE SEPARATOR - Installation guide     |     Kate Jennings 

 

Each separator is supplied with a sticker on each side identifying the separator and size.  
 

 

 

4

 

INSTALLATION 

 
The  EcoJet  grease  separator  must  be  installed  in  compliance  with local  water  authority 
regulations,  Safework  Australia  and  all  other  codes  of  practice.  Prior  to  installation, 
ensure that the local water authority approves each installation.  
 
The grease separator should be installed on level concrete.  
 
Before using the grease separator for the first time, fill with clean water. 
 
 

4.1 Location 
 

Ensure the location of the grease separator is positioned where a maintenance contractor 
can  easily  access  for  pump  out.  If  in  doubt,  contact  a  grease  removal  contractor  and 
obtain a written agreement that the grease separator is able to be serviced.  
 
All  above  ground  grease  separators  require  steps  and  a  platform  for  maintenance 
purposes, in accordance with AS 1657-1992. 
 
 
 

4.2 Connecting pipes 

 
Connecting pipes and pipe materials should be installed in accordance with AS 3500 and 
local plumbing codes.  
 

 

*IO: Inspection Opening 

*TWSP: Trade Waste Sampling Point 

 

I.O  

I.O /  TWSP 
 

Vent 

Summary of Contents for ECOJET

Page 1: ...ns NSW 2750 Tel 61 2 4747 4000 Fax 61 2 4747 4029 Email sales acoaus com au ACO Passavant Installation guide ECOJET GREASE SEPARATOR VERSION NO IMPLEMENTED BY REVISION DATE REASON 18 Kate Jennings 17...

Page 2: ...OJET GREASE SEPARATOR Installation guide Kate Jennings 2 Contents 1 GENERAL 3 2 SAFETY CONSIDERATIONS 3 3 SIZING 4 4 INSTALLATION 5 5 MAINTENANCE 7 6 WATER AUTHORITY APPROVALS 7 7 CONTACT INFORMATION...

Page 3: ...ivery and prior to installation check for damage that may have occurred during transportation or at the job site prior to installation Grease separators can be extremely large To avoid damage to the g...

Page 4: ...ECOJET GREASE SEPARATOR Installation guide Kate Jennings 4 3 SIZING 3 1 Sizing The correct sizing and regular emptying of a grease separator is vital to its correct and on going function...

Page 5: ...Before using the grease separator for the first time fill with clean water 4 1 Location Ensure the location of the grease separator is positioned where a maintenance contractor can easily access for...

Page 6: ...onnecting pipes and pipe materials should be installed in accordance with AS NZS 3500 and local plumbing codes Note Check manufacturers approvals for use in ground slab applications prior to use Coupl...

Page 7: ...approvals Some authorities have specicic requirements for applications within their catchment Below are some of these requirements but contact the local authority for case by case advice Water Corpora...

Page 8: ...100mm Ensure two are installed with each grease separator part number 3300 13 00 7 CONTACT INFORMATION For queries servicing assistance and spare parts contact ACO ACO Pty Ltd 134 140 Old Bathurst Ro...