24
Operation manual
ACO Clara
9.6.5 Magnet replacement
Follow the procedure of valve box and diaphragm
replacement (1 – 7, 9 -12).
1. Remove the diaphragm and pull out the diaphragm and the magnet
from the other side.
2. Set the new magnet
with the nut or bolt.
3. Insert the diaphragm and the magnet
between the solenoids. The projection
should be upward.
4. Fix the diaphragm of the
other side.
5. Insert the magnet sup-
port jig in four corners
between the magnet
and the core.
Follow the procedure
of valve box and diap-
hragm replacement
(15 – 24).
Make sure that the magnet is in the centre
of the solenoids. Failure to do so could result in
the damage on parts, short circuiting.
!
Summary of Contents for ClarA 19-38